Continuous and Discontinuous Capacity Control for High Speed Refrigeration Compressors

نویسندگان

  • H. Holdack-Janssen
  • H. Kruse
چکیده

The objective of this theoretical investigation was to find a capable and economical way of controlling high speed refrigeration compressors with a low number of cylinders. Compressors with 4 cylinders or more allow control by cutting-off one or two cylinder blocks because the remaining blocks maintain a sufficient smoothness of low speed fluctuation. The type of regulation to be found in this work should therefore apply primarily to twoand three-cylinder-compressors. Up to now the control of such compressors was performed only by externa 1 contra 1devices . These types of control do not affect the smoothness of low speed fluctuations, because they engage either before or after the compression. Application of external control affects all cylinders or only some of themwith respect to an application before or after the compression. External controls are characterized by a high energy input. Therefore they are economically not reasonab 1 e . Examples for those are throttling of the gas in the suction line and a discharge ill suction by-pass. To be economically efficient an internal controller action affecting the process of compression is preferred. Such an i nterna 1 contra 11 er action for 1 ow numbers of cylinders issupposedtoaffectall cylinderssimultaneously in order to achieve a sufficient smoothness of low speed fluctuations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

C 24 - 4 Research and Development of Variable - Speed Scroll

The adjustment and control mode of frequency conversion for an air-conditioner can make the refrigeration capacity adapt the variety of its load very well. Thus, it has many advantages such as low variety in in-door temperature, short time to reach the wished temperature, low energy consumption, low start electric current and low strike to electric source etc. This mode is widely used in room a...

متن کامل

The Design Of A New Generation Of Twin Screw Refrigeration Compressors

The design of two series of twin screw compressors for being used in refrigeration applications are reported in this paper. The capacity range for the open type series is from 85 to 4300 h m / 3 , and for the semi-hermetic series from 120 to 2600 h m / 3 . The rotor profile and other design parameters are optimized with the help of the software package SCCAD. Many new features are adopted in th...

متن کامل

Hybrid NMPC of a Supermarket Refrigeration System Using Sequential Optimization

Supermarket refrigeration systems are hybrid systems due to switching of the continuous dynamics and due to the presence of discretely switched actuators such as valves and compressors. The main control goal for these systems is to keep temperature and pressure levels within tight bounds while minimizing the wear of the compressors. In our previous work, a hierarchical model-predictive control ...

متن کامل

Advanced Analysis of Dew Point Control Unit of Hybrid Refrigeration Systems in Gas Refineries

In this paper, an advanced analysis of a novel hybrid compression-absorption refrigeration system (HCARS) for natural gas dew point control unit in a gas refinery is presented. This unit separates the heavy hydrocarbon molecules in the natural gas, which is traditionally carried out by natural gas cooling in a compression refrigeration cycle (CRS). The power input required for the refrigeration...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014