Randomized controlled trial of osteoconductive fixation screws for anterior cruciate ligament reconstruction: a comparison of the Calaxo and Milagro screws.

نویسندگان

  • Henry E Bourke
  • Lucy J Salmon
  • Alison Waller
  • Carl S Winalski
  • Heidi A Williams
  • James M Linklater
  • Amit Vasanji
  • Justin P Roe
  • Leo A Pinczewski
چکیده

PURPOSE To compare the outcome of 2 bioabsorbable screws for tibial interference fixation in anterior cruciate ligament reconstruction with reference to rate of absorption, osteoconductive properties, and clinical outcome. METHODS Patients undergoing primary anterior cruciate ligament reconstruction with hamstring autograft in a single unit were invited to participate in this study. Patients were randomized to receive either the Calaxo screw (Smith & Nephew, Andover, MA) or Milagro screw (DePuy Mitek, Raynham, MA) for tibial fixation. Patients were reviewed with subjective and objective evaluation by use of the International Knee Documentation Committee form, Lysholm score, KT-1000 arthrometry (MEDmetric, San Diego, CA), and clinical examination. Magnetic resonance imaging was performed at 1 year and computed tomography scanning at 1 week and at 6, 12, and 24 months. RESULTS Sixty patients agreed to participate in the study, with 32 patients randomized to the Calaxo screw and 28 to the Milagro screw for tibial fixation. There was no significant difference in subjective or objective clinical outcome between the 2 groups. At 24 months, 88% of Calaxo screws showed complete screw resorption compared with 0% of Milagro screws (P < .001). Tibial cysts were present in 88% of the Calaxo group and 7% of the Milagro group (P = .001). At 24 months, the mean volume of new bone formation for the Calaxo group was 21% of original screw volume. Ossification of the Milagro screw was unable to be accurately assessed as a result of incomplete screw resorption. CONCLUSIONS Both screws showed similar favorable objective and subjective outcomes at 2 years. The Calaxo screw resorbed completely over a period of 6 months and was associated with a high incidence of intra-tunnel cyst formation. The Milagro screw increased in volume over a period of 6 months, followed by a gradual resorption, which was still ongoing at 2 years. Both screws were associated with tunnel widening, and neither showed evidence of significant tunnel ossification. We conclude that, despite satisfactory clinical outcomes, the addition of "osteoconductive" materials to bioabsorbable screws is not associated with bone formation at the screw site at 2 years. LEVEL OF EVIDENCE Level I, randomized controlled trial.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic resonance imaging analysis of the bioabsorbable Milagro™ interference screw for graft fixation in anterior cruciate ligament reconstruction

Ligament graft fixation with bioabsorbable interference screws is a standard procedure in cruciate ligament replacement. Previous screw designs may resorb incompletely, and can cause osteolysis and sterile cysts despite being implanted for several years. The aim of this study was to examine the in vivo degradation and biocompatibility of the new Milagro interference screw (Mitek, Norderstedt, G...

متن کامل

Biomechanical Properties of a Novel Biodegradable Magnesium-Based Interference Screw

Magnesium-based interference screws may be an alternative in anterior/posterior cruciate ligament reconstruction. The well-known osteoconductive effects of biodegradable magnesium alloys may be useful. It was the purpose of this study to evaluate the biomechanical properties of a magnesium based interference screw and compare it to a standard implant. A MgYREZr-alloy interference screw and a st...

متن کامل

Efficacy of Osteoconductive Ceramics in Bioresorbable Screws for Anterior Cruciate Ligament Reconstruction

BACKGROUND Osteoconductive additives are used in resorbable interference screws for anterior cruciate ligament (ACL) reconstruction to improve graft incorporation and mitigate adverse effects. There are no published studies that compare biological performances of bioresorbable and biocomposite screws without artifacts due to different follow-up times and intrinsic patient characteristics. PUR...

متن کامل

Functional Outcome Following Arthroscopic ACL Reconstruction with Rigid Fix: A Retrospective Observational Study

  Background: No uniform consensus exists to decide type of fixation for arthroscopic anterior cruciate ligament reconstruction. Hypothsis: There is similar functional outcome after rigid fix compared to other methods of fixation which has been published. Study design: Retrospective observational study. Methods: A total of 50 patients underwent arthroscopic anterior cruciate ligament reconstruc...

متن کامل

Biomechanical analysis of femoral tunnel pull-out angles for anterior cruciate ligament reconstruction with bioabsorbable and metal interference screws.

BACKGROUND Fixation strength of metal and bioabsorbable interference screws has not been evaluated while varying the anterior cruciate ligament graft tension angle. HYPOTHESIS There is no difference in fixation strength between 2 types of interference screws for anterior cruciate ligament graft fixation while the graft tension angle is varied relative to the femoral tunnel. STUDY DESIGN Con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association

دوره 29 1  شماره 

صفحات  -

تاریخ انتشار 2013