An Evaluation of the Environmental Impact of Different Commercial Supermarket Refrigeration Systems Using Low Global Warming Potential Refrigerants

نویسندگان

  • Mohamed Beshr
  • Vikrant Aute
  • Omar Abdelaziz
  • Brian Fricke
  • Reinhard Radermacher
  • Mohamed BESHR
  • Vikrant AUTE
  • Omar ABDELAZIZ
  • Brian FRICKE
  • Reinhard RADERMACHER
چکیده

Commercial refrigeration systems consumed 1.21 Quads of primary energy in 2010 and are known to be a major source for refrigerant charge leakage into the environment. Thus, it is important to study the environmental impact of commercial supermarket refrigeration systems and improve their design to minimize any adverse impacts. The system's Life Cycle Climate Performance (LCCP) was presented as a comprehensive metric with the aim of calculating the equivalent mass of carbon dioxide released into the atmosphere throughout its lifetime, from construction to operation and destruction. In this paper, an open source tool for the evaluation of the LCCP of different airconditioning and refrigeration systems is presented and used to compare the environmental impact of a typical multiplex direct expansion (DX) supermarket refrigeration systems based on three different refrigerants as follows: two hydrofluorocarbon (HFC) refrigerants (R-404A, and R-407F), and a low global warming potential (GWP) refrigerant (N-40). The comparison is performed in 8 US cities representing different climates. The hourly energy consumption of the refrigeration system, required for the calculation of the indirect emissions, is calculated using a widely used building energy modeling tool (EnergyPlus). A sensitivity analysis is performed to determine the impact of system charge and power plant emission factor on the LCCP results. Finally, we performed an uncertainty analysis to determine the uncertainty in total emissions for both R-404A and N-40 operated systems. We found that using low GWP refrigerants causes a considerable drop in the impact of uncertainty in the inputs related to direct emissions on the uncertainty of the total emissions of the system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modelling of an Integrated Supermarket Refrigeration and Heating System Using Natural Refrigerants

This paper describes the development of a computer simulation model of an integrated supermarket refrigeration and heating system using natural refrigerants (namely ammonia and hydrocarbons). Initial resultS of the model's performance are presented, showing the influence of some of the operating parameters on system thermal efficiency. This will be validated using data collected from monitoring...

متن کامل

Exergy, exergoeconomic and exergoenvironmental studies and optimization of a novel triple-evaporator refrigeration cycle with dual-nozzle ejector using low GWP refrigerants

In this work, a novel dual-nozzle ejector enhanced triple-evaporator refrigeration cycle (DETRC) without separator is proposed to improve the performance of the conventional ejector one (CETRC). The performance of DETRC is analyzed and compared with CETRC in term of energy coefficient of performance (COPen). Under given operating conditions, the COPen improvement of the no...

متن کامل

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) – Summary of Phase II Testing Results

The Air-Conditioning, Heating, and Refrigeration Institute (AHRI) recently completed the second phase of its Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP). This industry-wide cooperative research program identified and evaluated promising alternative refrigerants over the past five years. Seventeen low-GWP refrigerants were tested during the second phas...

متن کامل

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) â•fi Summary of Phase I Testing Results

The Air-Conditioning, Heating, and Refrigeration Institute (AHRI) recently completed the first phase of its low global warming potential alternative refrigerants evaluation program (Low-GWP AREP). This industry-wide cooperative research program identified and evaluated promising alternative refrigerants’ performance over the past two years. Thirty-eight low-GWP refrigerants were tested during t...

متن کامل

Testing of Environment Friendly Refrigerant R290 for Water Cooler Application (RESEARCH NOTE)

This paper presents environment friendly refrigerant R290 as a solution to the environmental concerns like depletion of ozone layer and rise in global warming because of wide use of synthetic refrigerants R22 and R134a. The water cooler is the widely used refrigeration application in warm climatic countries. Refrigerant R22 and R134a are predominantly used refrigerants in water cooler refrigera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014