Validation of portable muscle tone measurement device for quantifying velocity-dependent properties in elbow spasticity.

نویسندگان

  • Hsin-Min Lee
  • Jia-Jin J Chen
  • Ming-Shaung Ju
  • Chou-Ching K Lin
  • Paul P W Poon
چکیده

The objective of this study is to develop a portable device for quantifying the velocity-dependent properties of spastic elbow muscles. Based on a motor-driven system, validation tests of the portable system such as accuracy and response of sensors were first examined. Furthermore, simulated modules (inertia, damper and spring) as well as elbow joints (15 control and 15 hemiplegic subjects) were manually stretched under four different frequencies (1/3, 1/2, 1 and 3/2 Hz) through 60 degrees range of motion. Joint resistance and displacement during sinusoidal stretch were collected for further analysis. Two quantitative parameters (i.e., viscous components under each frequency and averaged viscosity across four frequencies) were derived to estimate the velocity-dependent properties of elbow joint. Tests of simulated modules confirm the manual stretch protocol and data analysis are valid in estimating the velocity-dependent component during a sinusoidal stretch. Compared to normal control, viscous component in each stretch frequency and averaged viscosity were significantly higher in subjects with spasticity (P < 0.001). The viscous component and averaged viscosity were found highly correlated with the modified Ashworth scale. These findings suggest that measurements of viscous component and averaged viscosity during manual sinusoidal stretching using the portable device could be clinically useful in evaluating spasticity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of Portable Muscle Tone Measurement Device Based on a Motor-driven System

As a component of upper motor neuron syndrome, assessment of abnormality in muscle tone, including spasticity and rigidity, is a routine clinical examination. The aim of this study is to extend a sophisticated motor-driven measurement system, developed in our previous research, as a validation platform for developing a portable muscle tone measurement system. The main features of hand-held musc...

متن کامل

Quantitative analysis of the velocity related pathophysiology of spasticity and rigidity in the elbow flexors.

OBJECTIVE To quantify velocity dependent and position related properties of increased muscle tone measured during a constant velocity stretch. METHODS Elbow flexors were vertically stretched under four different velocities (40, 80, 120, and 160 degrees /s) through a 75 degrees range of motion in 12 patients with hemiparesis, 16 with parkinsonism, and 12 normal controls. From reactive torque m...

متن کامل

بررسی پایایی مقیاس اصلاح شده اشورت در ارزیابی اسپاستیسته عضلات در بیماران همی پلژیک

Background and Aim: Spasticity is a velocity-dependent increase in tonic stretch reflexes (muscle tone) with exaggerated tendon jerks, resulting from hyperexcitability of the stretch reflex. The measurement of spasticity is necessary to determine the effect of treatments. The Modified Ashworth Scale is the most widely used method for assessing muscle spasticity in clinical practice and research...

متن کامل

An approach for spasticity quantification based on the stretch reflex threshold

Spasticity is a common and complex motor disorder that affects more than 12 million persons in the world. There are several studies on spasticity quantification in the literature but there is still a need for measurement improvements. This paper presents the design of a mechatronic device for spasticity quantification, in joint of ankle, elbow and knees. This approach is based on the velocity d...

متن کامل

Evolution of Quantitative Approaches for Muscle Spasticity Measurement

About 20 years ago, I first joined the spasticity measurement research group at biosignal laboratory (leaded by Dr. Jia-Jin Jason Chen) of Institute of Biomedical Engineering, National Cheng Kung University. At that time, the limitation of clinical approach for spasticity evaluation was initially noted by the researchers [1]. We developed our first quantitative measurement system based on drive...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology

دوره 14 5  شماره 

صفحات  -

تاریخ انتشار 2004