Effects of carbon brush anode size and loading on microbial fuel cell performance in batch and continuous mode

نویسندگان

  • Vanessa Lanas
  • Yongtae Ahn
  • Bruce E. Logan
چکیده

The location of the geometric center of mass of the anode had a significant effect on power output. At equal position of the geometric center of the anode, larger brushes

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of batch vs. continuous mode of operation on microbial desalination cell performance treating municipal wastewater

Microbial desalination cells (MDCs) have  great potential as a cost-effective and green technology for simultaneous water desalination, organic matter removal and energy production. The aim of this study was to compare the performance of a MDC under batch and continuous feeding conditions. Hence, power and current output, coulombic efficiency, electron harvest rate, desalination rate and COD re...

متن کامل

Removal of High Concentrations of Phenol in Dual Chamber Microbial Fuel Cell

Background and purpose: Microbial fuel cell is one of the sustainable development technologies that can be used simultaneously for removal of many pollutants and generate electricity. The aim of this study was to determine the removal rate of high concentrations of phenol in a microbial fuel cell. Materials and methods: A dual chamber microbial fuel cell having Nafion proton exchange membrane ...

متن کامل

Effect of CO in the reformatted fuel on the performance of Polymer Electrolyte Membrane (PEM) fuel cell

There are several obstacles to the commercialization of PEM fuel cells.  One of the reasons is that the presence of carbon monoxide (CO) in the reformatted fuel, even at a very small scale, decreases the fuel cell performance. The aim of this paper is to investigate the effect of CO in reformatted fuel on PEM fuel cell performance. For this purpose, a steady state, one-dimensional and non-isoth...

متن کامل

Analysis of carbon fiber brush loading in anodes on startup and performance of microbial fuel cells

Flat carbon anodes placed near a cathode in a microbial fuel cell (MFC) are adversely affected by oxygen crossover, but graphite fiber brush anodes placed near the cathode produce high power densities. The impact of the brush size and electrode spacing was examined by varying the distance of the brush end from the cathode and solution conductivity in multiple MFCs. The startup time was increase...

متن کامل

Tetracycline Antibiotic Removal from Wastewater via Air-Cathode Microbial Fuel Cells

Background and objective: Tetracyclines are the second most used group of antibiotics in the world. This type of antibiotic has a weak attraction in the body and enters wastewater through urine and feces. This study investigated the effectiveness of tetracycline removal from wastewater by air-cathode microbial fuel cells. Materials and methods: The current study was bench-scale experimental re...