Mammography device use in Turkey, and quantity and quality analysis of mammography education.
نویسندگان
چکیده
PURPOSE To evaluate in detail the ways and methods of mammography education, to survey currently used mammography devices, and to determine the quality of mammography examinations in Turkey in order to increase the quality of said examinations and to offer guidance to standardization studies in Turkey. MATERIALS AND METHODS This study depended on the analysis of a questionnaire that was completed by volunteering medical centers. The questionnaire was mailed to all institutions in Turkey with a mammography device and which were registered with the Turkish Atomic Energy Commission and individual city health administration databases (n = 456). RESULTS It was not possible to determine the exact number of mammography devices in Turkey. In all, 270 questionnaires were completed and returned from the registered centers. Among the mammography devices declared (n = 291), automatic exposure control (AEC), spot view, and magnification view were not used at 21%, 34%, and 43% of the centers, respectively. Preoperative wire localization was not practiced at 180 centers (62%) despite the ability to do so. At 16% of the centers, mammograms were not labeled and at 57% of the centers labeling was handwritten. At 23% of the centers only small cassettes were used, and at 58% the heat and at 94% the humidity of film storage areas were inappropriate or unknown. At 25% of the centers light and at 15% radiation exposure of the film was present. Mammography quality control tests were performed at 40%, and in 70% control records were not well kept. There were no thermometers in 49% of the centers, no phantom breast at 80%, no sensitometer at 93%, and no densitometer at 81%. At 50% of the centers, regular periodic maintenance was not performed. Second look was performed consistently at 12% of the centers and BI-RADS (Breast Imaging Reporting and Data System) categorization was used at 40%. CONCLUSION The exact number of mammography devices is not officially known in Turkey, and it is apparent that registration of some devices was not made by the Turkish Atomic Energy Commission. Questionnaire responses about mammography education and procedures revealed that there was a serious lack of quality across regions. Education, accreditation, inspection, and sanctions are needed immediately to institute standardization and improve quality. This is a critical situation that should be addressed by the Turkish Society of Radiology.
منابع مشابه
Breast dose in conventional and digital mamography
Introduction: The amount of doses received in mammography is one of the biggest concerns in the world. According to some statistics, every 12 minutes a woman dies due to breast cancer. Mammography concerned to detect breast cancer at an early stage of the disease as well as for screening, however due to the risk of exposure, the increasingly and widespread use of mammography fo...
متن کاملمقایسه میزان دز جذبی پستان در دستگاه ماموگرافی معمولی و دیجیتال در شرایط مورد استفاده دستگاهها در تبریز
Background: The amount of doses received in mammography is one of the biggest concerns in the world. According to some statistics, every 12 minutes a woman dies due to breast cancer. Mammography concerned to detect breast cancer at an early stage of the disease as well as for screening, however due to the risk of exposure, the increasingly and widespread use of mammography for breast cancer scr...
متن کاملComparing the Effectiveness of Digital and Analog Mammography in Breast Cancer Diagnosis and Screening: A Systematic Review and Meta-Analysis
Background & Objectives: Breast cancer is the most common cancer among women and one of the leading causes of death in the productivity ages. Mammography screening is the main method for the diagnosis of breast cancer. While analog mammography counts as the standard method of screening, the digital one can be an alternative. This review compared the effectiveness and safety of these technologie...
متن کاملH-BwoaSvm: A Hybrid Model for Classification and Feature Selection of Mammography Screening Behavior Data
Breast cancer is one of the most common cancer in the world. Early detection of cancers cause significantly reduce in morbidity rate and treatment costs. Mammography is a known effective diagnosis method of breast cancer. A way for mammography screening behavior identification is women's awareness evaluation for participating in mammography screening programs. Todays, intelligence systems could...
متن کاملارزیابی دز و کیفیت تصویر در آزمون های ماموگرافی در مراکز ماموگرافی شهر تهران
Abstract Background: Breast cancer is one of the most common form of cancer among women. Diagnosis in the early stage of emergence is the most effective way to reduce the mortality caused by this disease. Mammography, the safest and most accurate imaging test for the identification of breast cancer, required high quality images along applying the lowest possible dose to sensitive tissues of the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Diagnostic and interventional radiology
دوره 13 3 شماره
صفحات -
تاریخ انتشار 2007