The PathoTec "Rapid I-D System" and two experimental test strips for ornithine decarboxylase and beta-galactosidase have been evaluated for accuracy and ability to identify 1,252 members of the Enterobacteriaceae obtained from fresh clinical specimens. Accuracy of identification with the commercially available test system was 94.7%; this level increased to 98.5% with the addition of the two experimental test strips. Average individual accuracy of the 12-strip test system on a side-by-side basis with similar conventional procedures was 98%. In addition, 103 gram-negative nonfermentors were accurately grouped. The PathoTec System was applicable to 95% of the primary isolation plates used and provided biochemical data within 4 h after inoculation. The conventional test procedures were applicable to 100% of the primary isolation plates used and produced data within 48 h.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the pathotec Rapid I-D system for identification of Enterobacteriaceae.

The PathoTec Rapid I-D System for identifying Enterobacteriaceae was evaluated with 471 cultures. In 4,910 individual test comparisons, 95.5% of the results agreed, with results of only two test strips, those for esculin hydrolysis and urease production, agreeing with conventional tests in less than 94% of the trials. The PathoTec system exhibited 94.3% accuracy in identifying these cultures in...

متن کامل

Rapid biotyping of Haemophilus influenzae and Haemophilus parainfluenzae with PathoTec strips and spot biochemical tests.

PathoTec strips and spot biochemical tests were evaluated for the ability to biotype Haemophilus influenzae and Haemophilus parainfluenzae. Indole, urease, and ornithine decarboxylase reactions were tested. The results of PathoTec strips compared favorably with those conventional methods; the percent agreements were as follows: indole, 100; urease, 99.5; and ornithine, 95.5. Spot tests were sim...

متن کامل

Rapid Biotyping of Haemophilus influenzae and Haemophilus parainfluenzae with PathoTec Strips and Spot Biochemical Tests BILLIE

PathoTec strips and spot biochemical tests were evaluated for the ability to biotype Haemophilus influenzae and Haemophilus parainfluenzae. Indole, urease, and ornithine decarboxylase reactions were tested. The results of PathoTec strips compared favorably with those conventional methods; the percent agreements were as follows: indole, 100; urease, 99.5; and ornithine, 97.5. Spot tests were sim...

متن کامل

Rapid penicillinase paper strip test for detection of beta-lactamase-producing Haemophilus influenzae and Neisseria gonorrhoeae.

A modified 1-min iodometric paper strip test for penicillinase activity was developed for detection of beta-lactamase-producing isolates of Haemophilus influenzae and Neisseria gonorrhoeae. The test is simple to perform and uses reagent-impregnated strips that may be stored for 1 year or more prior to use.

متن کامل

[Diagnosis of meningitis with reagent strips]

OBJECTIVE: To determine the usefulness of reagent strips in the evaluation of pleocytosis, cerebrospinal fluid glucose and protein levels for early and rapid diagnosis of meningitis in children. METHODS: We included cerebrospinal fluid samples of 164 children admitted to the outpatient clinic of Communicable Diseases of the General Pediatric Center (Fundação Hospitalar do Estado de Minas Gerais...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied microbiology

دوره 26 6  شماره 

صفحات  -

تاریخ انتشار 1973