Bedside sonographic measurement of optic nerve sheath diameter as a predictor of increased intracranial pressure in children.
نویسندگان
چکیده
STUDY OBJECTIVE We investigate the test performance of emergency physician-performed sonographic measurement of optic nerve sheath diameter for diagnosis of increased intracranial pressure. METHODS Children between the ages of 0 and 18 years with suspected increased intracranial pressure were prospectively recruited from the emergency department and ICU of an urban, tertiary-level, freestanding pediatric facility. Pediatric emergency physicians with goal-directed training in ophthalmic sonography measured optic nerve sheath diameter. Images were recorded and subsequently reviewed by a pediatric ophthalmologist and an ophthalmic sonographer, both of whom were blind to the patient's clinical condition. Measurements obtained by the ophthalmic sonographer were considered the criterion standard. An optic nerve sheath diameter greater than 4.0 mm in subjects younger than 1 year and greater than 4.5 mm in older children was considered abnormal. The diagnosis of increased intracranial pressure was based on results of cranial imaging or direct measurement of intracranial pressure. RESULTS Sixty-four patients were recruited, of whom 24 (37%) had a confirmed diagnosis of increased intracranial pressure. The sensitivity of optic nerve sheath diameter as a screening test for increased intracranial pressure was 83% (95% confidence interval [CI] 0.60 to 0.94); specificity was 38% (95% CI 0.23 to 0.54); positive likelihood ratio was 1.32 (95% CI 0.97 to 1.79) and negative likelihood ratio was 0.46 (95% CI 0.18 to 1.23). There was fair to good interobserver agreement between the pediatric emergency physician and ophthalmic sonographer (kappa 0.52) and pediatric ophthalmologist (kappa 0.64). CONCLUSION The sensitivity and specificity of bedside sonographic measurement of optic nerve sheath diameter is inadequate to aid medical decisionmaking in children with suspected increased intracranial pressure. Pediatric emergency physicians with focused training by a pediatric ophthalmologist familiar with ophthalmic sonography can measure optic nerve sheath diameter accurately.
منابع مشابه
Optic Nerve Sheath Ultrasound for the Bedside Diagnosis of Intracranial Hypertension: Pitfalls and Potential
Raised intracranial pressure is a complication not just of traumatic brain injury and other acute cerebral insults, but also of a number of general medical conditions. Bedside diagnosis can be difficult; early clinical signs may be misinterpreted, and reliance on cross-sectional imaging studies may further delay diagnosis. Ultrasound is a readily available imaging modality in most critical care...
متن کاملEffect of scuba-diving on optic nerve and sheath diameters
Background :There is not any data available about the effect of high bar pressure condition on intracranial pressure. In this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated. Methods : Twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. Only one perso...
متن کاملElevated Intracranial Pressure Diagnosis with Emergency Department Bedside Ocular Ultrasound
Bedside sonographic measurement of optic nerve sheath diameter can aid in the diagnosis of elevated intracranial pressure in the emergency department. This case report describes a 21-year-old female presenting with 4 months of mild headache and 2 weeks of recurrent, transient binocular vision loss. Though limited by patient discomfort, fundoscopic examination suggested the presence of blurred o...
متن کاملDynamic optic nerve sheath diameter responses to short-term hyperventilation measured with sonography in patients under general anesthesia
BACKGROUND Rapid evaluation and management of intracranial pressure (ICP) can help to early detection of increased ICP and improve postoperative outcomes in neurocritically-ill patients. Sonographic measurement of optic nerve sheath diameter (ONSD) is a non-invasive method of evaluating increased intracranial pressure at the bedside. In the present study, we hypothesized that sonographic ONSD, ...
متن کاملEffect of Positive End-Expiratory Pressure on the Sonographic Optic Nerve Sheath Diameter as a Surrogate for Intracranial Pressure during Robot-Assisted Laparoscopic Prostatectomy: A Randomized Controlled Trial
BACKGROUND Positive end-expiratory pressure (PEEP) can increase intracranial pressure. Pneumoperitoneum and the Trendelenburg position are associated with an increased intracranial pressure. We investigated whether PEEP ventilation could additionally influence the sonographic optic nerve sheath diameter as a surrogate for intracranial pressure during pneumoperitoneum combined with the Trendelen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of emergency medicine
دوره 53 6 شماره
صفحات -
تاریخ انتشار 2009