Clinical experience of e-PTFE membrane implant surgery for refractory glaucoma.
نویسندگان
چکیده
AIMS To evaluate the clinical efficacy of membrane tube implant made of expanded polytetrafluoroethylene (e-PTFE, Gore-Tex) membrane and silicone tube in treating refractory glaucoma. METHODS A retrospective chart review was performed on 43 eyes of 40 patients who underwent glaucoma tube shunt implant surgery using double layered e-PTFE membrane and silicone tube to treat refractory glaucoma. The surgeries were performed from May 1991 to September 1995, and the subjects were patients with terminal glaucoma without useful vision on the study eye. RESULTS The mean follow up period was 32.9 months. The Kaplan-Meier survival for intraocular pressure (IOP) control (IOP between 6 and 21mm Hg without significant complication) was 80.9% at 1 year, 73.9% at 2 years, and 62.2% at 3 years after surgery. After excluding three eyes of three patients who were dropped within 3 months after surgery and did not have any serious complication or problem in IOP control, the average preoperative IOP was 42.5 (SD 14.6) mm Hg and IOP on the last visit was 17.3 (10.2) mm Hg (p = 0.000, n = 40). The number of antiglaucoma medications before surgery (2.2 (0.6)) was reduced to 0.5 (0.8) on the last visit (p = 0.000). The IOP was controlled within the range of 6-21 mm Hg in 26 eyes (65.0%). In the remaining 14 eyes (35%), we could not control the IOP or additional surgery was needed to control the IOP or to treat severe complications. Two cases of endophthalmitis and three of phthisis were found as serious complications. The other complications were similar to those of other commercially available glaucoma implants. CONCLUSION A comparable clinical result was obtained with this new implant as with the other commercially available implants. This implant with a thin and non-rigid reservoir has a potential to reduce some complications associated with the large volume and rigid consistency of the other implants, although it is not yet proved. This membrane tube implant may be considered as another substitute in the surgery of refractory glaucoma.
منابع مشابه
In vivo biocompatibility assessment of (PTFE–PVDF–PP) terpolymer-based membrane with potential application for glaucoma treatment
The aim of the work was to evaluate the in vivo biological behaviour of polymeric membrane materials for glaucoma implants. The base material was biostable synthetic terpolymer (PTFE-PVDF-PP) with proved biocompability (PN-EN ISO 10993). The samples manufactured in the form a membrane were subjected to chemical and physical treatment to create an open pore system within the polymer matrix. As a...
متن کاملSimultaneous implant placement and vertical ridge augmentation with a titanium-reinforced membrane: a case report.
The present report demonstrates a clinical approach to achieve vertical ridge augmentation around endosseous implants. Two implants were placed, leaving the threads exposed, in the atrophic mandibular right posterior quadrant of a male patient. Both implants were covered with a titanium-reinforced expanded polytetrafluoroethylene (e-PTFE) membrane. Second-stage surgery was performed 12 months a...
متن کاملAhmed Glaucoma Valve with Adjunctive Amniotic Membrane for Refractory Glaucoma
PURPOSE To evaluate the efficacy and safety of Ahmed Glaucoma Valve (AGV) implantation with adjunctive use of preserved amniotic membrane for surgical management of refractory glaucoma. METHODS Seven patients (5 female subjects) with refractory glaucoma were included in the study. An AGV (model FP7) was implanted in the usual manner and was covered with two layers of cryopreserved human amnio...
متن کاملAhmed Glaucoma Valve Implant: Experience in East Africa
PURPOSE To describe short term outcomes of Ahmed Glaucoma Valve [AGV] implantation in East African patients. MATERIALS AND METHODS In this multi-center retrospective case series we reviewed eyes of Black African patients with refractory glaucoma, treated consecutively with Ahmed Glaucoma Valve implantation, in two centers in Kenya between January 2006 and October 2007. RESULTS About 25 case...
متن کاملClinical, Histologic and Histomorphometric Evaluation of Bone Strip Allograft with Resorbable Membrane in Horizontal Alveolar Ridge Augmentation: A Preliminary Study
Objective: Alveolar ridge preservation in patients with inadequate bone volume is one treatment option for successful implant placement and can be done by using bone graft materials. On the other hand, Ceno Bone has been recently produced by Hamanand Saz Baft Kish Co. as a bone bioimplant of allograft origin. This study aimed to assess the clinical, histologic and histomorphometric results of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 87 1 شماره
صفحات -
تاریخ انتشار 2003