Strategy for Eliminating Risks of Corrosion and Overprotection for Buried Modern Pipelines

نویسنده

  • Fumio Kajiyama
چکیده

The driving force that causes metals to corrode is a natural consequence of their temporary existence in metallic form. Application of cathodic protection (CP) as measures to stop corrosion has a very long history. The first application of impressed current system for protection of underground structures took place in England and in the United States, about 1910-1912. The first criterion for CP of steel pipelines, that is, −0.850V (vs. copper sulfate electrode) with the CP applied, was proposed by Kuhn in 1933 and has since been accepted and used worldwide on steel pipelines and structures in various soils and water. Kuhn‟s criterion has facilitated the application of CP for extending buried pipelines with the economic growth. Kuhn‟s criterion is referred to the protection potential criterion and in the scope of direct current (DC) corrosion protection. In the early 1900s, the effect of AC interference current on a metallic structure was known and to some degree had been quantified. In 1906, Hayden investigated to determine whether, and to what extent, AC currents passing between any metallic conductors (gas and water pipes, lead cables, etc.) and the ground would produce AC corrosion, due to the introduction of grounded AC systems using the developed single-phase railway motor. Hayden concluded iron is attacked less than lead. Up until the mid-1980s, the prevailing opinion was that, although AC current could cause corrosion of steel, the corrosion rate was a small percentage of an equivalent amount of DC and furthermore could be controlled by the application of CP in accordance with the protection potential criterion. Up to the mid1980s, corrosion failure on a pipeline was not attributed to AC corrosion, probably because the pipelines were bare or less well coated having sufficient grounding, such that induced voltages were not a practical problem. In 1986, corrosion failure on a polyethylene coated pipeline caused by induced AC interference currents resulting from AC powered rail transit system was first reported in Europe despite satisfying the protection potential criterion. Since then, pipeline failures caused by AC corrosion have been reported not only in Europe but in North America. Factors that contribute to AC corrosion include (1) high resistivity of pipe coating, and (2) the increased tendency to locate pipelines paralleling high voltage (HV) AC electric power lines and/or AC powered rail transit systems. It has been definitely shown by the occurrence of AC corrosion on a cathodically protected pipeline that AC corrosion cannot be prevented by CP in the presence of very high AC voltage of a pipeline. The necessity for establishment of criterion for AC corrosion protection has been realized ever since. However, there are no agreed-on criteria for AC corrosion protection. Recently, pipelines are being constructed in parallel with HVAC electric power lines and/or AC powered rail transit systems with thinner, high strength steel-walls, high resistivity coating with little or no corrosion allowance. This means that more attention must be paid to new threats, that is, AC corrosion and overprotection on modern pipelines. The authors have developed an advanced instrumentation for assessing the AC corrosion risk of buried pipelines, and established the new CP criterion based on coupon DC and AC current densities (coupon current density-based criterion). The most distinguished feature of the instrumentation is the simultaneous computation in a measuring unit of 20 ms regarding coupon DC current density and coupon AC current density corresponding to the commercial frequency of 50 Hz. The criterion eliminates all corrosion risks such as AC corrosion, DC stray current corrosion, microbiologically influenced corrosion etc., and overprotection risk. This paper details how the developed instrumentation enabled understanding of AC corrosion or protection level of a cathodically protected pipeline, and establishment of the new CP criterion. Particular emphasis in the presence of AC is placed on the necessity for understanding of (1) limitations of the protection potential criterion and CP, and (2) adverse effects leading to possible AC corrosion and hydrogen embrittlement under overprotection circumstances caused by increasing the CP level as protection measures against AC corrosion. Furthermore, the features of an advanced instrumentation for assessing the AC corrosion risk of buried pipelines are also described with an example of measured data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ANOVELMONITORINGTECHNIQUE TO DEFINE CP CRITERIA FOR BURIED PIPELINES UNDER AC CORROSION CONDITION

Abstract: The risks of alternating current (AC) corrosion and overprotection increasingly demand new criteria forcathodically protected pipelines. To assess the risk of AC corrosion, new cathodic protection (CP) criteria have beenproposed based on DC/AC current densities measurements using coupons. The monitoring system designed for thisproject was based on the instant-off method, with steel co...

متن کامل

A SURVEY ON THE EFFECT OF SOIL COMPOSITION IN CORROSION BEHAVIOR OF CATHODICALLY PROTECTED BURIED PIPELINES UNDER AC INDUCED CONDITION

Abstract: Due to the expansion of high voltage Alternating Current (AC) power transmission lines and cathodically protected buried pipelines, it is becoming more and more difficult to construct them with enough safe distances between them. Thus, the pipelines are frequently exposed to induced AC interferences, which result in perturbation of Cathodic Protection (CP) due to AC corrosion. To s...

متن کامل

The Investigation of Subsidence Effect on Buried Pipes in 3D Space

Buried pipes in the modern societies are considered as lifelines with a vital and essential role in the human life cycle. The performance of buried pipes is affected by many factors such as ground surface subsidence. In this paper, the effect of subsidence on pipelines is investigated using a three-dimensional numerical modeling developed in FLAC3D software for four types of most commonly used ...

متن کامل

An Electrochemical Measurement for Evaluating the Cathodic Disbondment of Buried Pipeline Coatings under Cathodic Protection

Steel pipelines are susceptible to corrosion by the action of corrosive substance in the environment and one of the most common failure modes in buried pipeline coatingis cathodic disbondment. Consequently, Electrochemical Impedance Spectroscopy (EIS) was used to assess the effect of three important parameters, the thickness of coating, the artificial defect ...

متن کامل

Numerical and Empirical Investigation of Flow Separation Phenomenon around Semi-buried Pipelines due to Steady Currents

In this paper, in order to understand the flow-pipe interaction more clearly, the variations on flow pattern around semi-buried pipelines due to steady current have physically and numerically been investigated. In physical modeling section, the experiments have been carried out in a flume with 10 meter length, 0.3 meter width and 0.5 meter depth using a P.V.C pipe with 6.35 cm in diameter (for ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011