SU-E-T-473: Performance Assessment of the TOPAS Tool for Particle Simulation for Proton Therapy Applications.

نویسندگان

  • J Perl
  • J Shin
  • J Schuemann
  • B Faddegon
  • H Paganetti
چکیده

PURPOSE The TOPAS Tool for Particle Simulation was developed to make Geant4 Monte Carlo simulation more readily available for research and clinical physicists. Before releasing this new tool to the proton therapy community, several test have been performed to ensure accurate simulations in a variety of proton therapy setups. METHODS TOPAS can model a passive scattering or scanning beam treatment head, model a patient geometry based on CT images, score dose, fluence, etc., save and replay a phase space, provides advanced graphics, and is fully four-dimensional (4D) to handle variations in beam delivery and patient geometry during treatment. An innovative control system meets requirements for ease of use, reliability and repeatability without sacrificing flexibility. To test the TOPAS code, we modeled proton therapy treatment examples including the UCSF eye treatment beamline (UCSFETB), the MGH STAR radiosurgery beamline and the MGH gantry treatment head in passive scattering and scanning modes. The simulations included time-dependent geometry and time- dependent beam current delivery. RESULTS At the UCSFETB, time- dependent depth dose distributions were accurately simulated with time- varying energy modulation from a rotating propeller. At the MGH STAR beamline, distal and proximal ranges agreed within measurement uncertainty and the shape of the simulated SOBP followed measured data. For the MGH gantry treatment head in passive scattering mode, SOBPs were simulated for the full set of range modulator wheel and second scatterer combinations. TOPAS simulation was within clinical required accuracy. For the MGH nozzle in scanning mode, a variety of scan patterns were simulated with fluence maps generated for cases including beam current modulation, energy modulation and target tracking. CONCLUSIONS Our results demonstrate the functionality of TOPAS. They show agreement with measured data and demonstrate the capabilities of TOPAS in simulating beam delivery in 3D and 4D. This work was supported by IH/NCI under R01 CA 140735-01.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Representing Range Compensators in the Topas Monte Carlo System

Double scattering-based proton therapy systems often use patient-specific range compensators for beam modulation. Range compensators adjust the depth in the tissue at which protons reach their Bragg peak. Accurately representing range compensators in Monte Carlo particle transport simulations is a vitally important problem for clinical treatment planning. This paper proposes two new computation...

متن کامل

SU-E-T-475: Nano-Dosimetric Track Structure Scoring including Biological Modeling with TOPAS-NBio.

PURPOSE To develop a nano-dosimetric Monte Carlo simulation package, TOPAS-nBio, based on the TOPAS (TOol for PArticle Simulations) framework that is being developed in a collaboration between the Massachusetts General Hospital (MGH), the SLAC National Accelerator Laboratory and the University of California, San Francisco. The goal is to incorporate biological processes on a sub-cell level that...

متن کامل

TOPAS Simulation of the Mevion S250 compact proton therapy unit

As proton therapy becomes increasingly popular, so does the need for Monte Carlo simulation studies involving accurate beam line modeling of proton treatment units. In this study, the 24 beam configurations of the Mevion S250 proton therapy system installed recently at our institution were modeled using the TOolkit for PArticle Simulation (TOPAS) code. Pristine Bragg peak, spread out Bragg peak...

متن کامل

Assessment of secondary particles in breast proton therapy by Monte Carlo simulation code using MCNPX

Background: The present study aimed to investigate the equivalent dose in vital organs, including heart and lung, due to secondary particles produced during breast proton therapy. Materials and Methods: The numerical ORNL female-phantom was improved and simulated using the Monte Carlo MCNPX code. The depth-dose profile of proton beams with different energies was simulated. The proper energy ran...

متن کامل

Evaluation of the effective dose during PBFT for brain cancer: A Monte Carlo Study

Introduction: Recently, an approach exploiting the proton therapy biological enhancement by using Boron atoms injected inside a tumor, has been proposed. Three alpha particles with an average energy around 4MeV are emitted from the point of reaction between a proton and boron. In addition, the 719 keV prompt gamma emitted by the proton Boron fusion reactions can be used for on-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part17  شماره 

صفحات  -

تاریخ انتشار 2012