Concrete Slender Wall Design – Back to the Future

نویسندگان

  • John W. Lawson
  • James Lai
  • SE FACI
چکیده

Slender concrete walls incorporated into tilt-up construction over the past 60 years have performed remarkably well under out-of-plane wind and seismic loads. While issues associated with seismic wall anchorage gave this form of construction a black-eye in the early days, the concrete walls themselves have always performed very well even as far back as their first use in the early 1900s. Yet the height-to-thickness limitations in 1985 and earlier model building codes were proved irrational and were removed. We as engineers expect building codes to evolve and advance the state of the art with each successive edition. The latest edition of ACI 318-08 has significantly revised the slender walls design procedures, yet not necessarily advancing the state of the art. The latest ACI 318 edition is largely revising slender wall design back to match equations found in the old 1997 UBC. This paper revisits the historical effort SEAOSC played in the development of the original slender wall provisions in the late 1970s, and why ACI is now revising their slender wall design provisions to agree with concepts developed over 30 years ago by SEAOSC. While these original concepts were based on empirical data from full-scale tests conducted in the early 1980s, only within the last five years have we really begun to fully understand the behavior of these thin concrete members when subjected to combined axial load and large horizontal forces. Historical Background Tilt-up panels were developed in the pre-WWI era as an erection technique to facilitate construction of large concrete wall panels without forming both sides in-place. In 1909, Col. Robert Aiken, described an innovative method of casting panels on tilting tables and then lifting them into place by means of specially designed mechanical jacks [Spears, 1980]. During the ensuing years, this technique was used for constructing target abutments, barracks, ammunition and gun houses, a mess hall, low cost housing, factory buildings and churches [Leabu, 1980.] After WWII, from the late 1940s to the 1960s, reinforced concrete tilt-up walls became a great innovation and construction advancement. Walls could be built, not with expensive wall-forms but cast on the concrete slabs on the ground and lifted into final position serving as architectural enclosures or elements. Developer clients on industrial and commercial buildings, particularly supermarkets and large warehouses, demanded taller walls than the maximum 16 feet 8 inch allowed for an 8-inch thick concrete wall, based on a height-to-thickness limit of 25. The first report “Technical Bulletin Number 2,” on tilt-up wall construction, covering the design and construction practice of tilt-up at that time, was published in 1949 by the Structural Engineers Association of Southern California. Height-to-Thickness Ratio Prior to 1985, building codes requirement for the design of concrete wall panels were based on arbitrary height-tothickness limitations. A minimum wall thickness of six inches was required. A height-to-thickness ratio limitation of 25 was imposed on bearing walls, and 30 for non-bearing walls. Such height-to-thickness ratios increased to 36 when second-order effects were accounted for in the wall panel design in accordance with ACI 318 Chapter 10’s requirements for slender compression members. The increased use of tilt-up concrete walls for commercial and industrial buildings led to trends toward designing slender walls using pseudo second-order analyses. At that time, a second order analysis was permitted by the building code, and that led to a trend towards designing slender walls with little or no concern for stiffness, thus possibly affecting long-term serviceability. In 1974, Portland Cement Association developed design aids for load bearing walls [Kripanarayanan, 1980]. The design aids were compatible

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New Code Changes under the 2009 IBC

The evolution of building codes typically produce design provisions that are expected to create safer and more accurate designs. We as engineers expect building codes to advance the state of the art with each successive edition. The 2009 International Building Code (IBC) and the Building Code Requirements for Structural Concrete (ACI 318-08) have significant revisions affecting the design of ti...

متن کامل

یادگیری از جامعه مورچگان در بهینه‌سازی دیوارهای حائل بتنی

: In the present paper, lessons are learnt from ant society so that humankind can optimize his engineering issues. As an example of such issues, a reinforced concrete retaining wall for which the application of optimization can reduce the costs involved is considered. Traditional design procedure for reinforced concrete retaining walls is unable to design an optimized wall unless a large trial ...

متن کامل

Nonlinear Finite Element Modeling of Different Cross-Sectional Shapes of Slender RC Columns Confined with CFRP Wraps

In the present study, non-linear finite element analyses are carried out on the slender reinforced concrete columns wrapped using CFRP composite with different cross-sectional shapes having the same area. Thickness of the CFRP wraps, concrete compressive strength, corner radius, loading condition, slenderness ratio and column size are the main parameters of this study. According to this, four d...

متن کامل

Effect of seismic sequences on fragility of Iranian code-conforming shear wall RC buildings

Background and objective: Estimating the vulnerability rate of urban textures in seismic incident following a major earthquake (aftershocks) is crucial in decision making and crisis management. For this purpose, it is necessary to calculate the vulnerability of buildings due to the successive incidents and to use them in the vulnerability estimation for probable future aftershocks. Seismic frag...

متن کامل

Structural Behavior of Axially Loaded Composite Concrete-steel Plate Shear Walls

composite concrete-steel plate shear walls are the most critical resisting structural members that resist lateral and axial loads. This type of wall consisting of two steel faceplates presenting the outer skin, infill concrete and shear connectors which are used to provide the composite action of the steel faceplates with infill concrete in order to increase the strength and to reduce the local...