A Comparison of Canal-centering ability of Two Nickel-Titanium Rotary Systems with Nickel Hand Instrumentation with Stainless Steel Hand Instrumentation in 10 to 25° Curved Canals using Kuttler's Cube
نویسنده
چکیده
AIMS The purpose of this study was to compare the canal centering abilities of rotary nickel-titanium (NiTi) files (ProFile 0.04 and 0.06 and Lightspeed LSX) and NiTi hand K-files in 10° to 25° curved canals. This was compared with the canal centering ability of stainless steel hand K-files using Kuttler's endodontic cube. SETTINGS AND DESIGN The teeth with a 10° to 25° of clinical mesiodistal curvature were used for this study. Each tooth was immersed in methylene blue dye for a period of 10 seconds, as recommended by Kuttler. MATERIALS AND METHODS The study sample comprised of 60 intact freshly extracted single rooted human mandibular premolars. The radiographs were traced on a tracing paper and the canal curvature was determined according to methodology introduced by Schneider. STATISTICAL ANALYSIS USED The statistical package SPSS PC + (Statistical package for social service, Version 4.01) was used for analysis. RESULTS Overall, Lightspeed LSX instruments showed superior canal centering ability and performed better than Profile series, hand NiTi K-files and hand stainless steel K-files. CONCLUSION The endodontic cube can be used as an effective method for analyzing the canal-centering ability of different endodontic instruments. Both the NiTi rotary instruments showed superior canal-centering ability than NiTi and stainless steel hand K-files. How to cite this article: Swarnkar A. A Comparison of Canal-centering ability of Two Nickel-Titanium Rotary Systems with Nickel Hand Instrumentation with Stainless Steel Hand Instrumentation in 10 to 25° Curved Canals using Kuttler's Cube. Int J Clin Pediatr Dent 2014;7(3):157-162.
منابع مشابه
An in-vitro Evaluation of canal transportation and centering ability of two rotary Nickel Titanium systems (Twisted Files and Hyflex files) with conventional stainless Steel hand K-flexofiles by using Spiral Computed Tomography.
BACKGROUND The purpose of this in-vitro study was to compare canal transportation and centering ability of Twisted and Hyflex Rotary Files with stainless steel hand k-flexofiles by using Spiral Computed Tomography. MATERIALS & METHODS A total of 90 freshly extracted human mandibular single rooted Premolar teeth were selected. The crowns were flattened with steel disks and a final dimension of...
متن کاملShaping Ability of NiTi Rotary versus Stainless-Steel Hand Instruments in Curved Root Canals of Extracted Teeth
Introduction: The purpose of this in-vitro study was to compare shaping ability of NiTi rotary Mtwo and FlexMaster with stainless steel hand K-Flexofile in curved root canals of extracted teeth. Materials and Methods: Mesiobuccal canals of 45 mandibular molar teeth were balanced into three groups of 15 each, with respect to the Schneider angle, canal access angle, height, dis-tance and radiu...
متن کاملA comparison of stainless steel hand and rotary nickel-titanium instrumentation using a silicone impression technique.
BACKGROUND Root canal preparation using rotary nickel-titanium instruments has been reported to be superior to hand instrumentation in terms of root canal shape, centring and frequency of procedural errors. The purpose of this study was to evaluate canal preparations using a sequential silicone impression technique to assess root canal morphology. METHODS Pre-operative canal impressions were ...
متن کاملA comparison of transportation and time of canal preparation with stainless steel hand instruments and Ni-Ti rotary systems (In – Vitro)
A comparison of transportation and time of canal preparation with stainless steel hand instruments and Ni-Ti rotary systems (In – Vitro) Dr. MR. Sharifian* - Dr. MH. Nekoofar* - Dr. P. Motahari** - Dr. A. Tavakoli*** *-Assistant Professor of Endodontics Dept. – Faculty of Dentistry – Tehran University of Medical Sciences. **- Assistant Professor of Oral and Maxillofacial Pathology Dept. – Facul...
متن کاملMeasure and compare the Degree of Root Canal Transportation and Canal-centering ability of Twisted, ProTaper, and Conventional Stainless Steel K Files using Spiral Computed Tomography: An in vitro Study.
AIM The aim of this study was to compare canal transportation and centering ability of Twisted files (TF) and ProTaper (PT) files with conventional stainless steel (SS) K files. MATERIALS AND METHODS Thirty mandibular premolar teeth with root curvature of 25 to 35° were selected. The samples were randomly divided into three groups of 10 each according to the type of files used for instrumenta...
متن کامل