Low Potential Stable Glucose Detection at Dendrimers Modified Polyaniline Nanotubes
نویسندگان
چکیده
The utilization of nanostructured materials for development of biosensors is a growing field in medical diagnostics. In this work a glucose biosensor based on bioactive polyglycerol (PGLD) and chitosan dendrimers (CHD) was developed. PGLD and CHD were bioconjugated with the enzyme glucose oxidase (GOx) to obtain dendrimers with glucose sensing properties. Polyaniline nanotubes (PANINT ́s) were used as electron mediator due to their high ability to promote electron-transfer reactions involving GOx. The PGLD-GOx and CHD-GOx were entrapped in PANINT ́s during template electrochemical polymerization of aniline. The prepared PGLDGOx/PANINT ́s and CHD-GOx/PANINT ́s biosensors exhibit a strong and stable amperometric response to glucose even at a low potential of +100 mV. The based PGLD-GOx/PANINT ́s and CHD-GOx/PANINT ́s biosensors showed a good performance in glucose concentrations range in human blood. A comparison of the sensitivities to glucose showed that both biosensors have a linearity range between 0.02 and 10 mM, though PGLD-GOx/PANINT ́s is more sensitive (10.41 vs. 7.04 nA.mM). The difference in the biosensor behavior and the high sensitivity of the PGLD-GOx/PANINT ́s may be due to the specific organization of GOx layer at surface of the modifier macromolecule PGLD and their distribution in PANINT ́s. The enzyme affinity for the substrate, K M app remains quite good after GOx immobilization on PGLD and CHD dendrimers and entrapment of the bioconjugates in PANINT ́s.
منابع مشابه
Immobilized enzyme-single-wall carbon nanotube composites for amperometric glucose detection at a very low applied potential.
The behaviour of support electrodes modified with randomly dispersed single-wall carbon nanotube meshes containing adsorbed glucose oxidase with respect to amperometric glucose detection at a low potential is demonstrated.
متن کاملUnusual neutral pH assisted electrochemical polymerization of aniline on a MWCNT modified electrode and its enhanced electro-analytical features.
Unusual electropolymerization of aniline to polyaniline (PANI) in a neutral pH solution has been successfully demonstrated using a multiwalled carbon nanotube (MWCNT) modified gold electrode (Au-MWCNT@PANIpH7). The modified electrode showed highly redox active surface confined peaks corresponding to the molecular transitions of leucoemeraldine-emeraldine and emeraldine-pernigraniline in pH 7 ph...
متن کاملPolyester Sulphonic Acid Interstitial Nanocomposite Platform for Peroxide Biosensor
A novel enzyme immobilization platform was prepared on a platinum disk working electrode by polymerizing aniline inside the interstitial pores of polyester sulphonic acid sodium salt (PESA). Scanning electron microscopy study showed the formation of homogeneous sulphonated polyaniline (PANI) nanotubes (∼90 nm) and thermogravimetric analysis (TGA) confirmed that the nanotubes were stable up to 2...
متن کاملDetection of Ascorbic Acid in Biological Samples by a New Modified Glassy Carbon Electrode
The present work describes the construction of a new modified electrode by casting the appropriate mixture of a metallocene, which has been introduced in the experimental part, as a mediator at the surface of glassy carbon (GC) electrode. The proposed modified GC electrode was used for the determination of ascorbic acid (AA) in phosphate buffer (PB) solution (pH = 4.0). When compared to bare GC...
متن کاملIncreased response/recovery lifetimes and reinforcement of Polyaniline Nano‐ fiber Films using Carbon Nanotubes
We have prepared high surface area, conductive, mechanically robust, responsive polyaniline-carbon nanotune composite films. These were produced by filtration from dilute dispersions of polyaniline nanofibers and single-walled carbon nanotubes. Unlike polyaniline alone, these composites are mechanically stable, maintain large intractable surfaces and exhibit greatly enhanced response/recovery b...
متن کامل