Material properties of the ovine mitral valve anterior leaflet in vivo from inverse finite element analysis.

نویسندگان

  • Gaurav Krishnamurthy
  • Daniel B Ennis
  • Akinobu Itoh
  • Wolfgang Bothe
  • Julia C Swanson
  • Matts Karlsson
  • Ellen Kuhl
  • D Craig Miller
  • Neil B Ingels
چکیده

We measured leaflet displacements and used inverse finite-element analysis to define, for the first time, the material properties of mitral valve (MV) leaflets in vivo. Sixteen miniature radiopaque markers were sewn to the MV annulus, 16 to the anterior MV leaflet, and 1 on each papillary muscle tip in 17 sheep. Four-dimensional coordinates were obtained from biplane videofluoroscopic marker images (60 frames/s) during three complete cardiac cycles. A finite-element model of the anterior MV leaflet was developed using marker coordinates at the end of isovolumic relaxation (IVR; when the pressure difference across the valve is approximately 0), as the minimum stress reference state. Leaflet displacements were simulated during IVR using measured left ventricular and atrial pressures. The leaflet shear modulus (G(circ-rad)) and elastic moduli in both the commisure-commisure (E(circ)) and radial (E(rad)) directions were obtained using the method of feasible directions to minimize the difference between simulated and measured displacements. Group mean (+/-SD) values (17 animals, 3 heartbeats each, i.e., 51 cardiac cycles) were as follows: G(circ-rad) = 121 +/- 22 N/mm2, E(circ) = 43 +/- 18 N/mm2, and E(rad) = 11 +/- 3 N/mm2 (E(circ) > E(rad), P < 0.01). These values, much greater than those previously reported from in vitro studies, may result from activated neurally controlled contractile tissue within the leaflet that is inactive in excised tissues. This could have important implications, not only to our understanding of mitral valve physiology in the beating heart but for providing additional information to aid the development of more durable tissue-engineered bioprosthetic valves.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Regional stiffening of the mitral valve anterior leaflet in the beating ovine heart.

Left atrial muscle extends into the proximal third of the mitral valve (MV) anterior leaflet and transient tensing of this muscle has been proposed as a mechanism aiding valve closure. If such tensing occurs, regional stiffness in the proximal anterior mitral leaflet will be greater during isovolumic contraction (IVC) than isovolumic relaxation (IVR) and this regional stiffness difference will ...

متن کامل

Stress-strain behavior of mitral valve leaflets in the beating ovine heart.

Excised anterior mitral leaflets exhibit anisotropic, non-linear material behavior with pre-transitional stiffness ranging from 0.06 to 0.09 N/mm(2) and post-transitional stiffness from 2 to 9 N/mm(2). We used inverse finite element (FE) analysis to test, for the first time, whether the anterior mitral leaflet (AML), in vivo, exhibits similar non-linear behavior during isovolumic relaxation (IV...

متن کامل

Transient stiffening of mitral valve leaflets in the beating heart.

Anterior mitral leaflet stiffness during isovolumic contraction (IVC) is much greater than that during isovolumic relaxation (IVR). We have hypothesized that this stiffening is due to transient early systolic force development in the slip of cardiac myocytes in the annular third of the anterior leaflet. Because the atrium is excited before IVC and leaflet myocytes contract for < or = 250 ms, th...

متن کامل

Anterior mitral leaflet curvature in the beating ovine heart: a case study using videofluoroscopic markers and subdivision surfaces.

The implantation of annuloplasty rings is a common surgical treatment targeted to re-establish mitral valve competence in patients with mitral regurgitation. It is hypothesized that annuloplasty ring implantation influences leaflet curvature, which in turn may considerably impair repair durability. This research is driven by the vision to design repair devices that optimize leaflet curvature to...

متن کامل

A finite strain nonlinear human mitral valve model with fluid-structure interaction

A computational human mitral valve (MV) model under physiological pressure loading is developed using a hybrid finite element immersed boundary method, which incorporates experimentally-based constitutive laws in a three-dimensional fluid-structure interaction framework. A transversely isotropic material constitutive model is used to characterize the mechanical behaviour of the MV tissue based ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 295 3  شماره 

صفحات  -

تاریخ انتشار 2008