North American neonatal extracorporeal membrane oxygenation (ECMO) devices and team roles: 2008 survey results of Extracorporeal Life Support Organization (ELSO) centers.

نویسندگان

  • D Scott Lawson
  • Andrea F Lawson
  • Rich Walczak
  • Craig McRobb
  • Patty McDermott
  • Ian R Shearer
  • Andrew Lodge
  • James Jaggers
چکیده

In early 2008, surveys of active extracorporeal membrane oxygenation (ECMO) centers in North America were conducted by electronic mail regarding neonatal ECMO equipment and professional staff. Eighty of 103 (78%) North American ECMO centers listed in the Extracorporeal Life Support Organization directory as neonatal centers responded to the survey. Of the responding centers, 82.5% routinely used roller pumps for neonatal ECMO, and the remaining 17.5% used centrifugal pumps. Silicone membrane oxygenators were used by 67% of the respondents, whereas 19% used micro-porous hollow fiber oxygenators, and 14% used polymethylpentene hollow fiber oxygenators. Of the silicone membrane oxygenator users, 86% used the Medtronic Ecmotherm heat exchanger, 10% used the Gish HE-4 heat exchanger, and 4% used the Terumo Conducer device. Sixty-four percent of the responding centers used some form of in-line blood gas monitoring. Six percent of the centers used a bubble trap in the arterial line, and 5% used an arterial line filter. A bladder was used by 85% of the centers, and 4% of these used a mechanical bladder box for servo regulation; the remaining 96% used pressure servo regulation. An air bubble detector was used by 88% of the responding centers. A surface coating was used by 44% of the centers on all their neonatal ECMO patients. Thirty-one percent of the centers use an activated clotting time of 180-220 seconds. At 54% of the responding centers, perfusionists were involved with the ECMO program, registered nurses were involved at 70% of the centers, and respiratory therapists were involved at 46% of the centers. Compared with a 2002 survey, silicone membrane use is declining, and the use of centrifugal blood pumps and coated ECMO circuits is becoming more apparent. ECMO teams are still multidisciplinary, made up of combinations of registered nurses, respiratory therapists, and perfusionists.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neonatal extracorporeal membrane oxygenation devices, techniques and team roles: 2011 survey results of the United States' Extracorporeal Life Support Organization centers.

In early 2011, surveys of active Extracorporeal Life Support Organization (ELSO) centers within the United States were conducted by electronic mail regarding neonatal Extracorporeal Membrane Oxygenation (ECMO) equipment and professional staff. Seventy-four of 111 (67%) U.S. centers listed in the ELSO directory as neonatal centers responded to the survey. Of the responding centers, 53% routinely...

متن کامل

North American neonatal extracorporeal membrane oxygenation (ECMO) devices: 2002 survey results.

In mid 2002, surveys of active extracorporeal membrane oxygenation (ECMO) centers in the United States and Canada were conducted via E-mail regarding neonatal equipment and personnel. Seventy-four out of 99 (75%) North American ECMO centers listed in the Extracorporeal Life Support Organization (ELSO) directory responded to the survey. Of the responding centers, 95% use roller pumps, and the re...

متن کامل

A 2007 survey of extracorporeal life support members: personnel and equipment.

Extracorporeal membrane oxygenation (ECMO) is used to support patients with cardiopulmonary failure in the intensive care unit. The purpose of this study is to determine what professional qualifications, equipment, and tests are used by established ECMO programs registered with the Extracorporeal Life Support Organization (ELSO). A survey link (Survey-Monkey) was e-mailed to the 110 registered ...

متن کامل

2004 survey of ECMO in the neonate after open heart surgery: circuitry and team roles.

Over the past 20 years, the bulk of the literature and texts published about extracorporeal membrane oxygenation (ECMO) has been written by physicians and nurses. The consensus of this body of printed information would suggest, among other things, that (1) despite significant advancements in extracorporeal technology, the standard ECMO circuit has remained fundamentally unchanged since original...

متن کامل

[Extracorporeal membrane oxygenation (ECMO): consolidation of a neonatal-pediatric program in Chile and report of three cases].

Extracorporeal membrane oxygenation (ECMO) improves survival in neonatal and pediatric patients with reversible severe respiratory or cardiac failure, in whom intensive treatment fails. Since 1999, a multidisciplinary team is trained to form the first neonatal-pediatric ECMO center in Chile, according to the norms of the Extracorporeal Life Support Organization (ELSO). During 2003 the first thr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 40 3  شماره 

صفحات  -

تاریخ انتشار 2008