Cephalad movement of morphine and fentanyl in humans after intrathecal injection.

نویسندگان

  • James C Eisenach
  • David D Hood
  • Regina Curry
  • Steven L Shafer
چکیده

BACKGROUND Despite decades of use, controversy remains regarding the extent and time course of cephalad spread of opioids in cerebrospinal fluid (CSF) after intrathecal injection. The purpose of this study was to examine differences between two often used opioids, morphine and fentanyl, in distribution in the CSF after intrathecal injection. METHODS Eight healthy volunteers received intrathecal injection of morphine (50 microg) plus fentanyl (50 microg) at a lower lumbar interspace. CSF was sampled through a needle in an upper lumbar interspace for 60-120 min. At the end of this time, a sample was taken from the lower lumbar needle, and both needles were withdrawn. CSF volume was determined by magnetic resonance imaging. Pharmacokinetic modeling was performed with NONMEM. RESULTS Morphine and fentanyl peaked in CSF at the cephalad needle at similar times (41 +/- 13 min for fentanyl, 57 +/- 12 min for morphine). The ratio of morphine to fentanyl in CSF at the cephalad needle increased with time, surpassing 2:1 by 36 min and 4:1 by 103 min. CSF concentrations did not correlate with weight, height, or lumbosacral CSF volume. The concentrations of morphine and fentanyl at both sampling sites were well described by a simple pharmacokinetic model. The individual model parameters did not correlate with the distance between the needles, CSF volume, patient height, or patient weight. CONCLUSIONS Fentanyl is cleared more rapidly from CSF than morphine, although their initial distribution in the first hour after injection does not differ greatly. The pharmacokinetic model demonstrates that mixing is the primary determinant of early concentrations and is highly variable among individuals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

How do we measure (the cost of) pain relief?

ber 1999) that demonstrate little difference in dermatomal spread in CSF of fentanyl compared with morphine after intrathecal injection. Thus, the extrapolation from pigs to humans and from models of CSF and tissue kinetics to clinical effects is far from certain. In summary, the article by Ummenhofer et al. is a seminal work in intrathecal pharmacokinetics. It directly incorporates location in...

متن کامل

بررسی مقایسه‌ای اثر تزریق 2 دوز مورفین اینتراتکال بر زمان خروج لوله نای پس از جراحی پیوند عروق کرونر

The object of the present study was to determine the effect of 2 doses of intrathecal morphine on extubation time and on postoperative analgestic requirements after coronary artery bypass graft surgery. This prospective, randomized, double blind placebo-control study was carried out on 60 adult patients(ASA II, ASA III) without emergency surgery, valvular heart disease, contraindication...

متن کامل

Cervicomedullary intrathecal injection of morphine produces antinociception in the orofacial formalin test in the rat.

BACKGROUND High cervical and medullary drug delivery has been advocated for the treatment of refractory head and neck pain in humans. Currently, parallel models in animals have not been developed to support this methodology. We combined an accepted animal model of pain of cranial origin with a novel technique of neuraxial drug delivery to address this issue. METHODS Male Wistar rats were impl...

متن کامل

Perioperative analgesia after intrathecal fentanyl and morphine or morphine alone for cesarean section

OBJECTIVES Intrathecal morphine is used in the postoperative management of pain after caesarean section (CS), but might not be optimal for intraoperative analgesia. We hypothesized that intrathecal fentanyl could supplement intraoperative analgesia when added to a local anesthetic and morphine without affecting management of postoperative pain. METHODS This prospective, randomized, double-bli...

متن کامل

OBSTETRICS Intrathecal morphine reduces breakthrough pain during labour epidural analgesia

Methods. This was a randomized, double-blind, placebo-controlled trial. Subjects were randomized to receive either 100 mg of morphine (MS) or placebo (PLCB) with the spinal injection of bupivacaine and fentanyl. Assessments included need for supplementation during labour analgesia, use of pain medications for 24 h after delivery, and side-effects. The primary endpoint was the rate of breakthrou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 99 1  شماره 

صفحات  -

تاریخ انتشار 2003