Determination of synthetic phenolic antioxidants and relative metabolites in sewage treatment plant and recipient river by high performance liquid chromatography-electrospray tandem mass spectrometry.

نویسندگان

  • Runzeng Liu
  • Ting Ruan
  • Shanjun Song
  • Yongfeng Lin
  • Guibin Jiang
چکیده

Robust analytical methods were developed for the determination of eight emerging synthetic phenolic antioxidants (SPAs) and three metabolites in sewage sludge, effluent and river water matrices. Accelerated solvent extraction was employed for the extraction of the target analytes from sludge, dichloromethane/hexane=3:1 (extraction solvent) and 90°C (extraction temperature) were used after optimization. Silica gel packed column was chosen for the subsequent clean-up procedure for sludge extract. For the water sample analysis, liquid-liquid extraction combined with silica gel clean-up was used. The targets were determined by optimized high performance liquid chromatography-tandem mass spectrometry method in negative electrospray ionization mode. The method quantification limits of the 11 analytes ranged from 0.1 to 23 ng/L, 0.1 to 20 ng/L and 0.1 to 15 ng/g for sewage effluent, river water and sludge matrices, respectively. The total recoveries of the pretreatment varied from 63 to 106%, with relative standard deviations less than 17% for the three matrices at different spiking levels. Nine targets including 2,6-di-tert-butyl-4-methylphenol (BHT), 3,5-di-tert-butyl-4-hydroxybenzaldehyde (BHT-CHO), 2,6-di-tert-butyl-1,4-benzoquinone (BHT-Q), 2,6-di-tert-butyl-4-hydroxy-4-methyl-2,5-cyclohexadienone (BHT-quinol), 3-tert-butyl-4-hydroxyanisole (BHA), 4-tert-octylphenol (4-tOP), 2,2'-methylenebis(6-tert-butyl-4-methylphenol) (AO 2246), 4,4'-butylidenebis(2-(1,1-dimethylethyl)-5-methyl-phenol) (AO 44B25) and 1,3,5-trimethyl-2,4,6-tris(3,5-di-tert-butyl-4-hydroxybenzyl)benzene (AO 330) were identified in the collected samples, with concentrations ranging 1.1-2325 ng/g and 0.4-2510 ng/L for sludge and water matrices, respectively. Sewage effluent was considered as a possible contamination source of certain SPA homologues and relative metabolites to the recipient aquatic systems.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation

The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...

متن کامل

Relative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation

The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Determination of Phenolic Content in Different Barley Varieties and Corresponding Malts by Liquid Chromatography-diode Array Detection-Electrospray Ionization Tandem Mass Spectrometry.

A simple and reliable method for the simultaneous determination of nine phenolic compounds in barley and malted barley was established, using liquid chromatography-diode array detection-electrospray ionization tandem mass spectrometry (HPLC-DAD-ESI-MS/MS). The phenolic compounds can be easily detected with both systems, despite significant differences in sensitivity. Concentrations approximatel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1381  شماره 

صفحات  -

تاریخ انتشار 2015