Tear film, contact lens, and patient factors associated with corneal staining.
نویسندگان
چکیده
PURPOSE The purpose of this study was to examine ocular surface and tear film, contact lens, care solution, medical, and patient-related factors that are associated with corneal staining in contact lens wearers. METHODS In this cross-sectional/nested case-control study, in addition to the assessment of corneal staining with fluorescein, a variety of tear film and ocular surface, contact lens, and patient-related factors were examined. Poisson regression models were used to examine the relation between corneal staining and these factors. RESULTS Data from 413 patients were eligible for the analyses described. The average age was 30.6 ± 11.1 years, and 277 (67.1%) of the patients were women. Several factors were shown to be related to increased corneal staining in multivariate modeling, including increased daily wearing times (P = 0.0006), lower income (P = 0.0008), lissamine green conjunctival staining (P = 0.002), contact lens deposition (P = 0.007), increased tear meniscus height (P = 0.007), and decreased hydrogel nominal water content (P = 0.02). The wearing of silicone hydrogels (as opposed to hydrogels) was protective against corneal staining (P = 0.0004). Notably, neither contact lens care solutions nor disinfectants were associated with corneal staining. CONCLUSIONS Corneal staining in contact lens wearers continues to be a frequent, but not well understood, outcome. These data suggest that contact lens factors (water content, material, wearing time, and deposition) are more generally associated with corneal staining than are contact lens care solutions or other ocular surface and tear film, demographic, or medical factors.
منابع مشابه
Tear film, contact lens, and patient-related factors associated with contact lens-related dry eye.
PURPOSE To examine tear film, contact lens, medical, and patient-related factors associated with self-reported contact lens-related dry eye. METHODS Four hundred fifteen contact lens wearers were recruited and enrolled in this phase of a larger cross-sectional study. A variety of tear film (e.g., interferometry, osmolality, phenol red thread, meibography, fluorescein, and lissamine green stai...
متن کاملThe influence of long-term corneal contact lens wearing on the stability and quality of tear film in Qinghai
This study was designed to explore the influence of long-term corneal contact lens (CL) wearing on the stability and quality of tear film in Qinghai. Thirty subjects with CL over five years and thirty myopia subjects without CL as control were recruited in our study. Basic tear secretion test, tear film break-up time (TBUT), and corneal fluorescein staining were determined. For further evaluati...
متن کاملTear film inflammatory mediators during continuous wear of contact lenses and corneal refractive therapy.
OBJECTIVES To study changes in tear film inflammatory mediators following continuous wear of silicone-hydrogel lenses and corneal refractive therapy with reverse geometry contact lenses. DESIGN A prospective, case-control study. METHODS Twenty-eight subjects had worn silicone-hydrogel lenses on a 30-night continuous wear basis. Thirty-two subjects had worn corneal refractive therapy lenses ...
متن کاملHypoxia, overnight wear, and tear stagnation effects on the corneal epithelium: data and proposed model.
PURPOSE : To explore the possible mechanisms that may lead to overnight contact lens-associated corneal morbidity by examining data from several corneal epithelial permeability experiments obtained under different environmental and lens fitting paradigms. METHODS : Epithelial permeability was assessed by using fluorometry to determine the fluorescein penetration rate from the tear film into t...
متن کاملCorneal Cell Adhesion to Contact Lens Hydrogel Materials Enhanced via Tear Film Protein Deposition
Tear film protein deposition on contact lens hydrogels has been well characterized from the perspective of bacterial adhesion and viability. However, the effect of protein deposition on lens interactions with the corneal epithelium remains largely unexplored. The current study employs a live cell rheometer to quantify human corneal epithelial cell adhesion to soft contact lenses fouled with the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 52 2 شماره
صفحات -
تاریخ انتشار 2011