Ultrasensitive detection of CrO4(2-) using a microcantilever sensor.

نویسندگان

  • H F Ji
  • T Thundat
  • R Dabestani
  • G M Brown
  • P F Britt
  • P V Bonnesen
چکیده

Microcantilevers modified with a self-assembled monolayer respond sensitively to specific ion concentrations. Here, we report the detection of trace amounts of CrO4(2-) using microcantilevers modified with a self-assembled monolayer of triethyl-12-mercaptododecylammonium bromide. The self-assembled monolayer was prepared on a silicon microcantilever coated with a thin layer of gold on one side. The microcantilever undergoes bending due to sorption of CrO4(2-) ions on the monolayer-modified side. It was found that a concentration of 10(-9) M CrO4(2-) can be detected using this technology in a flow cell. Other anions, such as Cl-, Br-, CO3(2-) (or HCO3-), and SO4(2-), have minimal effect on the deflection of this cantilever. The mechanics of the bending and the chemistry of cantilever modification are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of CrO4(2-) using a hydrogel swelling microcantilever sensor.

Hydrogels containing various mounts of tetraalkylammonium salts were used to modify microcantilevers for measurements of the concentration of CrO4(2-) in aqueous solutions. These microcantilevers undergo bending deflection upon exposure to solutions containing various CrO4(2-) concentrations as a result of swelling or shrinking of the hydrogels. The microcantilever deflection as a function of t...

متن کامل

Designing a Label Free Aptasensor for Detection of Methamphetamine

A label-free electrochemical nucleic acid aptasensor for the detection of methamphetamine (MA) by the immobilization of thiolated self-assembled DNA sequences on a gold nanoparticles-chitosan modified electrode is constructed. When MA was complexed specifically to the aptamer, the configuration of the nucleic acid aptamer switched to a locked structure and the interface of the biosensor changed...

متن کامل

Using Boehmite Nanoparticles as an Undercoat, and Riboflavin as a Redox Probe for Immunosensor Designing: Ultrasensitive Detection of Hepatitis C Virus Core Antigen

In this study a label-free electrochemical Immunosensor for ultrasensitive detection of Hepatitis C virus core antigen in serum samples was fabricated by using a simple approach. In this method a low-cost and sensitive immunosensor was fabricated based on a boehmite nanoparticles (BNPs) modified glassy carbon. The BNPs provide a specific platform with increased surface area which is capable of ...

متن کامل

An anti E. coli O157:H7 antibody-immobilized microcantilever for the detection of Escherichia coli (E. coli).

A silicon microcantilever sensor was developed for the detection of Escherichia coli O157:H7. The microcantilever was modified by anti-E. coli O157:H7 antibodies on the silicon surface of the cantilever. When the aquaria E. coli O157:H7 positive sample is injected into the fluid cell where the microcantilever is held, the microcantilever bends upon the recognition of the E. coli O157:H7 antigen...

متن کامل

Optical and Microcantilever-Based Sensors for Real-Time In Situ Characterization of High-Level Waste

Fundamental research is being conducted to develop sensors for cesium and strontium that can be used in real-time to characterize highlevel waste (HLW) process streams. Two fundamentally different approaches are being pursued, having in common the dependence on highly selective molecular recognition agents. In one approach, an array of chemically selective sensors with sensitive fluorescent pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 73 7  شماره 

صفحات  -

تاریخ انتشار 2001