Heterogeneous electron transfer kinetics at the ionic liquid/metal interface studied using cyclic voltammetry and scanning electrochemical microscopy.

نویسندگان

  • Alasdair W Taylor
  • Fulian Qiu
  • Jingping Hu
  • Peter Licence
  • Darren A Walsh
چکیده

The electrochemical behavior of a redox-active, ferrocene-modified ionic liquid (1-ferrocenylmethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide) in acetonitrile and in an ionic liquid electrolyte (1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide) is reported. Reversible electrochemical behavior was observed in each electrolyte with responses typical of those for unmodified ferrocene observed in each medium. In the ionic liquid electrolyte, the diffusion coefficient of the redox-active ionic liquid increased by a factor of 5 upon increasing the temperature from 27 to 90 degrees C. The kinetics of electron transfer across the ionic liquid/electrode interface were studied using cyclic voltammetry, and the standard heterogeneous electron transfer rate constant, k (0) was determined to be 4.25 x 10 (-3) cm s (-1). Scanning electrochemical microscopy was then also used to probe the heterogeneous kinetics at the interface between the ionic liquid and the solid electrode and conventional kinetic SECM theory was used to determine k (0). The k (0) value obtained using SECM was higher than that determined using cyclic voltammetry. These results indicate that SECM is a very useful technique for studying electron transfer dynamics in ionic liquids.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitive Voltammetric Detection of Indomethacin Using TiO2 Nanoparticle Modified Carbon Ionic Liquid Electrode

In this work, a TiO2 nanoparticle modified carbon ionic liquid electrode (CILE) was employed as a sensitive sensor for the investigation of the electrochemical behavior of indomethacin (IND). This nanocomposite sensor has been fabricated by incorporation of TiO2 nanoparticles and the ionic liquid 1-hexylpyridinium hexafluorophosphate (HPFP). The surface of the electrode was studied by scanning ...

متن کامل

Electrochemical Behavior and Highly Sensitive Voltammetric Determination of Doxepin in Pharmaceutical Preparations and Blood Serum Using Carbon Ionic Liquid Electrode

In this manuscript, the electrocatalytic oxidation of doxepin (DOX) was studied at a carbon ionic liquid electrode, fabricated using graphite, and the ionic liquid 1-octylpyridinium hexaflourophosphate (OPFP). The surface of the proposed electrode was characterized by scanning electron microscopy. Differential pulse voltammetry was applied as an analytical technique for quantification of sub-mi...

متن کامل

Electrochemical Behavior and Highly Sensitive Voltammetric Determination of Doxepin in Pharmaceutical Preparations and Blood Serum Using Carbon Ionic Liquid Electrode

In this manuscript, the electrocatalytic oxidation of doxepin (DOX) was studied at a carbon ionic liquid electrode, fabricated using graphite, and the ionic liquid 1-octylpyridinium hexaflourophosphate (OPFP). The surface of the proposed electrode was characterized by scanning electron microscopy. Differential pulse voltammetry was applied as an analytical technique for quantification of sub-mi...

متن کامل

Electrodeposition of germanium at elevated temperatures and pressures from ionic liquids.

The electrodeposition of germanium at elevated temperatures up to 180 °C and pressures was studied from the ionic liquids 1-butyl-1-methylpyrrolidinium dicyanamide and 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide containing [GeCl4(BuIm)2] (where BuIm = 1-butylimidazole) or GeCl4. Cyclic voltammetry (CV), electrochemical quartz crystal microbalance (EQCM), rotating ring-disk e...

متن کامل

Cyclic voltammetry and scanning electrochemical microscopy of ferrocenemethanol at monolayer and bilayer-modified gold electrodes

Ferrocenemethanol was chosen to study quantitatively the kinetics of the heterogeneous electron transfer at monoand bilayermodified gold electrodes. The monolayer was prepared by tetradecanethiol adsorption on the gold surface and the bilayer was formed by phospholipid adsorption on the first layer. The apparent electron transfer rate constants at the modified gold electrodes were measured by c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of physical chemistry. B

دوره 112 42  شماره 

صفحات  -

تاریخ انتشار 2008