Accuracy of Intraocular Lens Power Formulas Involving 148 Eyes with Long Axial Lengths: A Retrospective Chart-Review Study

نویسندگان

  • Chong Chen
  • Xian Xu
  • Yuyu Miao
  • Gaoxin Zheng
  • Yong Sun
  • Xun Xu
چکیده

Purpose. This study aims to compare the accuracy of intraocular lens power calculation formulas in eyes with long axial lengths from Chinese patients subjected to cataract surgery. Methods. A total of 148 eyes with an axial length of >26 mm from 148 patients who underwent phacoemulsification with intraocular lens implantation were included. The Haigis, Hoffer Q, Holladay 1, and SRK/T formulas were used to calculate the refractive power of the intraocular lenses and the postoperative estimated power. Results. Overall, the Haigis formula achieved the lowest level of median absolute error 1.025 D (P < 0.01 for Haigis versus each of the other formulas), followed by SRK/T formula (1.040 D). All formulas were least accurate when eyes were with axial length of >33 mm, and median absolute errors were significantly higher for those eyes than eyes with axial length = 26.01-30.00 mm. Absolute error was correlated with axial length for the SRK/T (r = 0.212, P = 0.010) and Hoffer Q (r = 0.223, P = 0.007) formulas. For axial lengths > 33 mm, eyes exhibited a postoperative hyperopic refractive error. Conclusions. The Haigis and SRK/T formulas may be more suitable for calculating intraocular lens power for eyes with axial lengths ranging from 26 to 33 mm. And for axial length over 33 mm, the Haigis formula could be more accurate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical results using the Holladay 2 intraocular lens power formula.

PURPOSE To analyze the accuracy of the Holladay 2 formula, which has been proposed as an improvement over the original Holladay formula. METHODS This retrospective analysis comprised 317 eyes operated on by 1 surgeon using 1 technique and 1 intraocular lens style in a specialty practice. Because the Holladay 2 formula has yet to be published, its accuracy can only be analyzed using the commer...

متن کامل

Accuracy of intraocular lens power estimation in eyes having phacovitrectomy for rhegmatogenous retinal detachment.

PURPOSE To evaluate the accuracy of intraocular lens power estimation in eyes having phacovitrectomy for rhegmatogenous retinal detachment. METHODS Retrospective case review of 100 consecutive eyes that underwent phacovitrectomy for rhegmatogenous retinal detachment. Axial lengths were measured using optical biometry and/or ultrasound A-scan. Achieved and predicted refraction were compared to...

متن کامل

Accuracy of Intraocular Lens Power Calculation Formulas in Primary Angle Closure Glaucoma

PURPOSE To compare the accuracy of intraocular lens (IOL) power calculation formulas in eyes with primary angle closure glaucoma (ACG). METHODS This retrospective study compared the refractive outcomes of 63 eyes with primary ACG with the results of 93 eyes with normal open angles undergoing uneventful cataract surgery. Anterior segment biometry including anterior chamber depth, axial length,...

متن کامل

Accuracy of formulae for secondary intraocular lens power calculations in pediatric aphakia

PURPOSE To compare the accuracy of axial length vergence formulas versus refractive vergence formulas for secondary intraocular lens (IOL) implantation in pediatric aphakia. METHODS This retrospective comparative study, evaluated 31 eyes of 31 patients aged ≤3.5 years, who had undergone secondary IOL implantation. The median absolute error (MedAE) was compared between axial length vergence fo...

متن کامل

Accuracy of intraocular lens power calculation in paediatric cataract surgery.

AIMS To determine the accuracy of intraocular lens (IOL) power calculation in a group of pseudophakic children. METHODS A retrospective analysis of biometric and refractive data was performed on 52 eyes of 40 infants and children, who successfully underwent cataract extraction and IOL implantation. The following parameters were included: age at the time of surgery, keratometry, axial length, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015