Monaural Beamforming in Bimodal Cochlear Implant Users: Effect of (A)symmetric Directivity and Noise Type

نویسندگان

  • Elke M J Devocht
  • A Miranda L Janssen
  • Josef Chalupper
  • Robert J Stokroos
  • Erwin L J George
چکیده

OBJECTIVE To evaluate monaural beamforming in bimodally aided cochlear implant (CI) users. DESIGN The study enrolled twelve adult bimodal listeners with at least six months of CI-experience and using a contralateral hearing aid (HA) most of the daytime. Participants were uniformly fitted with the same CI speech processor and HA, giving access to an identical monaural beamformer in both ears. A within-subject repeated measures design evaluated three directional configurations [omnidirectional, asymmetric directivity (in CI alone) and symmetric directivity (in both CI and HA)] in two noise types [stationary and fluctuating]. Bimodal speech reception thresholds (SRT) as well as listening effort ratings were assessed in a diffuse noise field. RESULTS Symmetric monaural beamforming provided a significant SRT improvement of 2.6 dB SNR, compared to 1.6 dB SNR for asymmetric monaural beamforming. Directional benefits were similarly observed in stationary and fluctuating noise. Directivity did not contribute to less listening effort in addition to improvement in speech intelligibility. Bimodal performance was about 7 dB SNR worse in fluctuating than in stationary noise. CONCLUSIONS Monaural beamforming provided substantial benefit for speech intelligibility in noise for bimodal listeners. The greatest benefit occurred when monaural beamforming was activated symmetrically in both CI and HA. Monaural beamforming does not bridge the gap between bimodal and normal hearing performance, especially in fluctuating noise. Results advocate further bimodal co-operation. TRIAL REGISTRATION This trial was registered in www.trialregister.nl under number NTR4901.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advanced Beamformers for Cochlear Implant Users: Acute Measurement of Speech Perception in Challenging Listening Conditions

OBJECTIVE To investigate the performance of monaural and binaural beamforming technology with an additional noise reduction algorithm, in cochlear implant recipients. METHOD This experimental study was conducted as a single subject repeated measures design within a large German cochlear implant centre. Twelve experienced users of an Advanced Bionics HiRes90K or CII implant with a Harmony spee...

متن کامل

Bilaterally Combined Electric and Acoustic Hearing in Mandarin-Speaking Listeners: The Population With Poor Residual Hearing

The hearing loss criterion for cochlear implant candidacy in mainland China is extremely stringent (bilateral severe to profound hearing loss), resulting in few patients with substantial residual hearing in the nonimplanted ear. The main objective of the current study was to examine the benefit of bimodal hearing in typical Mandarin-speaking implant users who have poorer residual hearing in the...

متن کامل

Head shadow enhancement with low-frequency beamforming improves sound localization and speech perception for simulated bimodal listeners.

Many hearing-impaired listeners struggle to localize sounds due to poor availability of binaural cues. Listeners with a cochlear implant and a contralateral hearing aid - so-called bimodal listeners - are amongst the worst performers, as both interaural time and level differences are poorly transmitted. We present a new method to enhance head shadow in the low frequencies. Head shadow enhanceme...

متن کامل

Impact of a Moving Noise Masker on Speech Perception in Cochlear Implant Users

OBJECTIVES Previous studies investigating speech perception in noise have typically been conducted with static masker positions. The aim of this study was to investigate the effect of spatial separation of source and masker (spatial release from masking, SRM) in a moving masker setup and to evaluate the impact of adaptive beamforming in comparison with fixed directional microphones in cochlear ...

متن کامل

EFFECT OF A UDITORY-VERBAL REHABILITATION ON VOICE PARAMETERS IN CHILD COCHLEAR IMPLANT USERS

This study aimed to evaluate the effects of auditory-verbal rehabilitation on voice parameters after implantation with cochlear implants 2 and 5 months after rehabilitation and compare them with normal voice children (under 12 years of age). A perceptive and electroacoustic evaluation of voice was carried out through a digital analysis after implantation and rehabilitation. The study was pe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016