Comparisons of physical imaging properties among three kinds of imaging plates used in photostimulable phosphor systems for dental radiography.

نویسندگان

  • Keiichi Nishikawa
  • Toshiki Ooguro
  • Kinya Kuroyanagi
چکیده

The purpose of this study was to compare the physical imaging properties of three kinds of imaging plates (IPs) used with two photostimulable phosphor systems for dental radiography: HR-V, used with the Digora, BAS-SR, and ST-V, used with the DenOptix for intraoral radiography and panoramic radiography, respectively. Sensitivity to X-ray, gradient, modulation transfer function (MTF), noise power spectrum (NPS), noise-equivalent quanta (NEQ), and detective quantum efficiency (DQE) were compared. All imaging plates were read using the DenOptix scanner with inactive automatic range control (ARC). The scanning resolution was set at 300 dpi. Decay of image information by room light was also compared at inactive and active ARC settings. BAS-SR showed the lowest sensitivity, the lowest gradient, the highest MTF, and the highest NPS. ST-V showed the highest sensitivity, the highest gradient, the lowest MTF, and the lowest NPS. HR-V was the second best for all imaging properties examined in this study. NEQ and DQE of BAS-SR were lowest, and those of ST-V were highest at low spatial frequencies. However, BAS-SR showed relatively constant NEQ and DQE while those of ST-V decreased remarkably at high spatial frequencies. NEQ and DQE of HR-V were the second best at low spatial frequencies and the best at high spatial frequencies. Therefore, we concluded that HR-V has the best imaging properties for dental radiography among three kinds of IPs evaluated in this study. However, the light decay speed of image information with HR-V was remarkably faster than with BAS-SR. To adopt HR-V for a system with which IPs are treated in an ordinary room, the light decay should be taken into account.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality comparison of direct digital panoramic radiography and computed radiography panoramic

BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...

متن کامل

Comparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption

Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...

متن کامل

Comparison of Different Imaging Techniques for the Evaluation of Proximity between Molars and the Mandibular Canal

Background and Aim: To compare the radiographic distance from the inferior part of mandibular second and third molars to the superior border of mandibular canal on radiographs obtained by conventional periapical radiographs, intraoral photostimulable phosphor plate (Intraoral PSP) and panoramic photostimulable phosphor plate (Panoramic PSP). Subjects and Methods: The study was carried out on 25...

متن کامل

Reproducibility of pixel values for two photostimulable phosphor plates in consecutive standardized scannings Reprodutibilidade dos valores de “pixels” de duas placas de fósforo fotoestimuláveis em leituras padronizadas consecutivas

The objective of the present study was to determine the reproducibility of the pixel values obtained with the Digora system (Soredex, Finland). Exposures were standardized, with variation in exposure and scanning time of two photostimulable phosphor plates containing a stepwedge image. The smallest variation in pixel values ranged from 50 to 75%, with the widest variations being observed in les...

متن کامل

A Comparative Study of Diagnostic Accuracy of Cone Beam Computed Tomography and Intra Oral Digital Radiography Phosphor Storage Plates in Detecting Strip Perforation in Endodontically-Treated Teeth

Background and purpose: Perforation impairs the prognosis of endodontic treatments, so, timely and accurate diagnosis is important. For this purpose, various radiographic diagnostic tools have been studied to select the method that has the least complications and helps in making the most accurate diagnosis. This study aimed to compare the accuracy of cone beam computed tomography (CBCT) and int...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Bulletin of Tokyo Dental College

دوره 43 1  شماره 

صفحات  -

تاریخ انتشار 2002