The geometry of the humeral head and the design of prostheses.

نویسندگان

  • S N Roberts
  • A P Foley
  • H M Swallow
  • W A Wallace
  • D P Coughlan
چکیده

The articular surface of the humeral head is usually described as facing posteromedially, making an angle of between 16 degrees and 35 degrees with the transepicondylar plane. At hemiarthroplasty the articular surface also appears to be offset posteriorly with respect to the humeral shaft. Coracoid impingement may occur if this offset is not accommodated. An analysis was made of 29 cadaveric humeri using an industrial co-ordinate measuring machine. The position of the centre of the head was defined with respect to the humeral shaft and transepicondylar plane. The humeral articular surface was found to be retroverted by 21.4 degrees and its centre offset posteriorly by 4.7 mm. Previous interpretation of retroversion did not take into account the posterior displacement, and this may be of importance in improving future prosthetic design.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Osteochondritis Dissecans of the Humeral Head: A Case Report and Review of the Literature

  Osteochondritis dissecans (OCD) is a common joint disorder in knee, ankle and elbow, however it can be rarely found in glenohumeral joint. In this study, we report an asymptomatic case of humeral head OCD, which was detected incidentally following a trauma. X-rays showed an area of lucency around an oval bony fragment measuring about 1 cm on the superior aspect of the humeral head. However, ...

متن کامل

Intrathoracic Displacement of Fractured Right Humeral Head: A Case Report

Intrathoracic displacement of the humeral head is a very uncommon condition and can be life threatening due to lungor heart injuries. There is a report of this condition where intrathoracic bone fragment was missed. Because of rareincidence there is no guideline for approach and treatment of this condition.We hereby present a case of intrathoracic displacement of fractured hum...

متن کامل

A Case study of Performance Improvement of Femur Prosthesis

Nowadays, the placement of artificial prostheses in human skeleton, etc. is common due to different reasons such as fractures or deficiencies. Prostheses are structures that assist the performance of organs by reconstruction of some body parts through different methods to enable the organ to re-obtain its performance completely or partially and, since the use of external prostheses might lead t...

متن کامل

Numerical Study of the tongue geometry effects on the cavitation and performance of a centrifugal pump in off-design conditions

In this study, the effects of the volute tongue geometry variation on the head, efficiency, velocity distribution and cavitation structure of a centrifugal pump in the steady flow behavior under off-design conditions have been investigated. Numerical simulation modeling based on the  turbulence model with a hybrid grid is used to simulate the flow within the modeled pump. The flow is simulated ...

متن کامل

Comparison of the Effectiveness of teflon piston and titanium stapes prosthesis in hearing improvement

Background & objectives: The aim of this study was to compare the effectiveness of two stapes prostheses in hearing improvement of patients undergoing stapes surgery for otosclerosis.   Materials & Methods: In this retrospective and descriptive study, the charts of 291 stapedectomies performed by one surgeon (first author) from 1997 to 2011 in Imam Khomeini and Apadana hospitals of Ahvaz were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 73 4  شماره 

صفحات  -

تاریخ انتشار 1991