چکیده

BACKGROUND Modern nonfluoroscopic mapping systems construct 3D electroanatomic maps by tracking intracardiac catheters. They require specialized catheters and/or dedicated hardware. We developed a new method for electroanatomic mapping by merging detailed 3D models of the endocardial cavities with fluoroscopic images without the need for specialized hardware. This developmental work focused on the right atrium because of the difficulties in visualizing its anatomic landmarks in 3D with current approaches. METHODS AND RESULTS Cardiac MRI images were acquired in 39 patients referred for radiofrequency catheter ablation using balanced steady state free-precession sequences. We optimized acquisition and developed software for construction of detailed 3D models, after contouring of endocardial cavities with cross-checking of different imaging planes. 3D models were then merged with biplane fluoroscopic images by methods for image calibration and registration implemented in a custom software application. The feasibility and accuracy of this merging process were determined in heart-cast experiments and electroanatomic mapping in patients. Right atrial dimensions and relevant anatomic landmarks could be identified and measured in all 3D models. Cephalocaudal, posteroanterior, and lateroseptal diameters were, respectively, 65+/-11, 54+/-11, and 57+/-9 mm; posterior isthmus length was 26+/-6 mm; Eustachian valve height was 5+/-5 mm; and coronary sinus ostium height and width were 16+/-3 and 12+/-3 mm, respectively (n=39). The average alignment error was 0.2+/-0.3 mm in heart casts (n=40) and 1.9 to 2.5 mm in patient experiments (n=9), ie, acceptable for clinical use. In 11 patients, reliable catheter positioning and projection of activation times resulted in 3D electroanatomic maps with an unprecedented level of anatomic detail, which assisted ablation. CONCLUSIONS This new approach allows activation visualization in a highly detailed 3D anatomic environment without the need for a specialized nonfluoroscopic mapping system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Potency of integrating three-dimensional cardiac magnetic resonance imaging into electroanatomic mapping to perform catheter ablation in pediatrics

Background Radio-frequency catheter ablation (RFCA) in children is difficult because the size of heart chamber change with age and the catheter made for adults is not appropriate for a child. Three-dimensional (3D) images for electroanatomic mapping (EAM) have been used to create from images of multi-detector computed tomography (MDCT) which need to perform entailed by contrast medium injection...

متن کامل

Three-dimensional image integration: a first experience with guidance of atrial fibrillation ablations.

The treatment of atrial fibrillation (AF) can be challenging, with a rate control strategy not being optimal for all patients and antiarrhythmic drugs frequently ineffective and possessing serious adverse effects. A fluoroscopic or electroanatomic catheter-based approach is rapidly becoming one of the preferred treatments of AF.1-3 However, success rates are still not ideal and complications du...

متن کامل

Advances in Imaging to Assist Atrial Fibrillation Ablation

Catheter ablation procedures to treat atrial fibrillation require sophisticated imaging for guidance. These imaging techniques have evolved from basic two-dimensional to complex three-dimensional methods that may involve fusion of data from different modalities such as computed tomography, magnetic resonance imaging, fluoroscopy, echocardiography and electroanatomical mapping. Summation of erro...

متن کامل

Catheter Ablation of Arrhythmias Exclusively Using Electroanatomic Mapping: A Series of Cases

BACKGROUND Catheter ablation is a treatment that can cure various cardiac arrhythmias. Fluoroscopy is used to locate and direct catheters to areas that cause arrhythmias. However, fluoroscopy has several risks. Electroanatomic mapping (EAM) facilitates three-dimensional imaging without X-rays, which reduces risks associated with fluoroscopy. OBJECTIVE We describe a series of patient cases whe...

متن کامل

Electro-anatomic mapping systems in arrhythmias.

Electroanatomic mapping systems have permitted and facilitated difficult interventional ablation procedures for more than a decade. Initially, their use has been in arrhythmias in which the ablation target is difficult to identify, such as ventricular tachycardias in structural heart disease, atypical atrial flutters, or arrhythmias in patients with complex congenital heart defects. In the rece...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 112 24  شماره 

صفحات  -

تاریخ انتشار 2005