Aortic root characteristics of human pulmonary autografts.

نویسندگان

  • G S Carr-White
  • A Afoke
  • E J Birks
  • S Hughes
  • A O'Halloran
  • S Glennen
  • S Edwards
  • M Eastwood
  • M H Yacoub
چکیده

BACKGROUND After pulmonary autograft replacement of the aortic valve and root, the pulmonary artery (PA) wall is subjected to higher pressures. Concern exists that this may lead to structural and functional changes in the implanted autograft and subsequent aortic root dilatation and neoaortic regurgitation. We therefore assessed root dimensions and neoaortic regurgitation, morphological structure, and mechanical behavior in patients who underwent the Ross operation. METHODS AND RESULTS Seventy-four patients who were randomized to undergo aortic valve replacement with an aortic homograft or a pulmonary autograft were followed up echocardiographically for up to 4 years and had their aortic root dimensions measured at the level of the annulus, sinuses, and sinotubular junction. In a separate series of 18 patients who underwent pulmonary autograft surgery and 8 normal organ donors, samples from the PA and aorta were analyzed for medial wall thickness, distribution of the staining of collagen and elastin, and elastin fragmentation. Finally, stress-strain curves were obtained from samples of the PA and aorta from 9 patients who underwent pulmonary autograft surgery and from 1 patient in whom a 4-month-old autograft was explanted. No patient in either group had aortic dilatation at any level of >20% or more than mild aortic regurgitation at up to 4 years of follow-up. The aortic media was thicker in both autografts and normal donors (P:<0.01), and there was a trend for the PA media to be thicker in the autograft group. Elastic fiber in all aortas showed little or no variation, whereas in the PA, there was considerable variation in fragmentation. Patients with higher preoperative PA pressures tended to have lower fragmentation scores (chi(2) P:<0.01). The lower stiffness modulus, higher stiffness modulus, and maximum tensile strength of the aorta was 34% to 38% higher than that of the PA (P:<0.01); however, the 4-month-old autograft appeared to show adaptation in mechanical behavior. CONCLUSIONS In our series of patients, there was no significant progressive dilatation of the aortic root. We demonstrated differences in the anatomic structure and mechanical behavior of the PA in vitro and highlighted histological and mechanical modes of adaptation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanics of the pulmonary autograft valve in the aortic position.

Pulmonary autograft valve replacement has been simulated by implanting the pulmonary valve into the aortic position of the same cadaver heart from both human and porcine sources. The forces acting on the pulmonary valve leaflets have been calculated on the basis of a triaxial ellipsoid mathematical model. These forces on the pulmonary autograft valve were shown to be essentially similar to thos...

متن کامل

The modified Ross operation using a Dacron prosthetic vascular jacket does prevent pulmonary autograft dilatation at 4.5-year follow-up.

OBJECTIVE Following the Ross operation, pulmonary autografts tend to dilate over time. This study researches the fate of the pulmonary autograft - at 4.5 years following the modified Ross operation - with special reference to the impact of the modification on (a) pulmonary autograft dilatation, (b) the neo-aortic root geometry, (c) neo-aortic valve function and (d) the coronary artery reserve. ...

متن کامل

Long-term results of pulmonary autograft for aortic valve replacement.

Eighty-five survivors who left hospital after pulmonary autograft replacement for severe aortic regurgitation have been followed critically. Five patients died in the first five years and 80 were followed for six to 11 years. Important aortic regurgitation occurred only early and was always related to technical malpositioning of one autograft cusp. Seven patients with fascial pulmonary valves h...

متن کامل

Right ventricular function after pulmonary autograft replacement of the aortic valve.

BACKGROUND The pulmonary autograft operation (the Ross procedure) involves excision of a portion of the right ventricular (RV) outflow tract, prolonged cross-clamp times, and insertion of a pulmonary homograft. There is concern about the effect of such operations on right ventricular function. METHODS AND RESULTS Twenty-five patients undergoing either pulmonary autograft or homograft replacem...

متن کامل

Time course of aortic valve function and root dimensions after subcoronary ross procedure for bicuspid versus tricuspid aortic valve disease.

BACKGROUND The freestanding aortic root, which is the currently preferred operative technique for pulmonary autografts, is reported to dilate and potentially promote aortic insufficiency, which has led to a controversial debate on the appropriate surgical technique, especially for congenital bicuspid aortic valve disease. Desirable data on the time course of valve function and root dimensions f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 102 19 Suppl 3  شماره 

صفحات  -

تاریخ انتشار 2000