Limb Angular Deformity Correction Using Dyna-ATC: Surgical Technique, Calculation Method, and Clinical Outcome

نویسندگان

  • Hoon Park
  • Hyun Woo Kim
  • Hui-Wan Park
  • Ki Seok Lee
چکیده

PURPOSE Dyna-ATC is a unilateral external fixator with angulator, lengthener, and translator, which allows for angular correction and compensation of the secondary displacement during angular correction. The purpose of this study is to introduce surgical technique and calculation methods and to evaluate the clinical outcome of angular deformity correction using Dyna-ATC. MATERIALS AND METHODS The amounts of secondary displacement were calculated with the distances between axis of correction of angulation, Center of Rotational Angulation, and osteotomy and the amount of angular deformity. The rate of angular correction was determined to distract the corticotomy at 1 mm/day. Clinical and radiographic evaluation was performed on 13 patients who underwent deformity correction using Dyna-ATC. There were 8 proximal tibia vara, 1 tibia valga, 2 varus and 4 valgus deformities on distal femur. One patient underwent pelvic support femoral reconstruction. Concomitant lengthening was combined in all femur cases. Mean age at surgery was 17.5 years (7 to 64). RESULTS All but one achieved bony healing and normal alignment with the index procedure. Mean mechanical axis deviation improved from 31.9 mm to 3.0 mm. The average amount of angular correction was 11.0° on tibiae and 10.0° on femora. The average length gain on femora was 6.4 cm, and the healing index averaged to 1.1 mo/cm. One patient underwent quadricepsplasty and one patient had three augmentation surgeries due to poor new bone formation. CONCLUSION We believe that Dyna-ATC is a useful alternative to bulky ring fixators for selective patients with angular deformity less than 30 degrees in the coronal plane around the knee joint.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgical Planning in Deformity Correction Osteotomies using Forward Kinematics and Inverse Kinematics

Patients with cerebral palsy or arthritis have deformities in lower limb which cause unstable gait or posture and pains. Surgeons perform a deformity correction osteotomy with surgical plan. But sometimes they find the unexpected angular or rotational deformation after surgery. The problems are that there is no method to predict the result of a surgical plan and also there are so many factors t...

متن کامل

Treatment of 30 Angular Limb Deformities of the Antebrachium and the Crus in the Dog Using Circular External Fixators

Objective: To evaluate frame constructs, surgical technique, postoperative care, complications, treatment duration, and outcome of circular external fixation (CEF) for treatment of 30 antebrachial and crural angular deformities in dogs. Study Design: Retrospective study. Sample Population: Twenty-seven dogs with limb deformities. Methods: Medical records of dogs that underwent surgery with CEF ...

متن کامل

Deformity' Correction by the Ilizarov Technique

Definition of Deformity Evaluation of Lower Limb Deformities Indications for Correction of Lower Limb Deformities Preoperative Planning Planning the Level of Osteotomy Other Factors in Determining the Level of the Osteotomy Determining the True Plane of the Deformity Translation Deformities . Angulation/Translation Deformities Multi-Apical Angular Deformities Joint Laxity Deformities of the Kne...

متن کامل

Guided growth for valgus deformity correction of knees in a girl with osteopetrosis: a case report

Autosomal dominant osteopetrosis (Albers-Schönberg disease) classically displays the radiographic signs of osteosclerosis. The main ADO complications involve the skeleton: low-impact bone fractures, scoliosis and hip osteoarthritis. Management of osteopetrosis-related orthopedic problems is a surgical challenge due to increased bone density. The healing process is very slow in these patients be...

متن کامل

Computer-assisted surgical correction of an antebrachial deformity in a dog.

OBJECTIVE To report the use of three dimensional (3D) computed tomographic (CT) imaging, computer simulation and rapid prototype modelling to aid surgical correction of a complex antebrachial deformity in a dog. METHODS A six-year-old, 13 kg spayed female Chihuahua crossbreed dog was presented for worsening forelimb gait and exercise intolerance. Both forelimbs had gross angular limb deformit...

متن کامل