Compensators: An alternative IMRT delivery technique
نویسندگان
چکیده
Seven years of experience in compensator intensity-modulated radiotherapy (IMRT) clinical implementation are presented. An inverse planning dose optimization algorithm was used to generate intensity modulation maps, which were delivered via either the compensator or segmental multileaf collimator (MLC) IMRT techniques. The in-house developed compensator-IMRT technique is presented with the focus on several design issues. The dosimetry of the delivery techniques was analyzed for several clinical cases. The treatment time for both delivery techniques on Siemens accelerators was retrospectively analyzed based on the electronic treatment record in LANTIS for 95 patients. We found that the compensator technique consistently took noticeably less time for treatment of equal numbers of fields compared to the segmental technique. The typical time needed to fabricate a compensator was 13 min, 3 min of which was manual processing. More than 80% of the approximately 700 compensators evaluated had a maximum deviation of less than 5% from the calculation in intensity profile. Seventy-two percent of the patient treatment dosimetry measurements for 340 patients have an error of no more than 5%. The pros and cons of different IMRT compensator materials are also discussed. Our experience shows that the compensator-IMRT technique offers robustness, excellent intensity modulation resolution, high treatment delivery efficiency, simple fabrication and quality assurance (QA) procedures, and the flexibility to be used in any teletherapy unit.
منابع مشابه
Evaluation of treatment planning system monitor unit calculations for three intensity modulated radiotherapy delivery techniques
Background: We have validated the monitor unit calculations from a commercially available treatment planning system (TPS) for three intensity modulated radiotherapy (IMRT) planning techniques for tangential breast irradiation by using ionization chamber measurements. Materials and Methods: Treatment plans were generated for forty-two breast patients by a forward planned field in field ...
متن کاملQuantitative analysis of brass compensators for commissioning of the Pinnacle planning system for IMRT
Brass compensators for beam modulation present an alternative method for IMRT treatment planning to traditional dynamic leaf modulation. In this work, we present a detailed method to commission the Pinnacle treatment planning system for IMRT using brass compensators. Beam attenuation from various brass thicknesses were measured using an ion chamber, as well as a MapCHECK device, for a represent...
متن کاملPotential advantages of volumetric arc therapy in head and neck cancer.
BACKGROUND Intensity-modulated radiation therapy (IMRT) uses solid compensators or multileaf collimators to modulate the intensity of radiation in each field, delivering highly conformal dose distributions. This technique allows treating volumes with concave shapes when the target is close to a critical structure. The movement of multileaf collimator under computer control can modulate the dose...
متن کاملDelivery time comparison for intensity-modulated radiation therapy with/without flattening filter: a planning study.
The treatment delivery time of intensity-modulated radiation therapy (IMRT) with a multileaf collimator (MLC) is generally longer than that of conventional radiotherapy. In theory, removing the flattening filter from the treatment head may reduce the beam-on time by enhancing the output dose rate, and then reduce the treatment delivery time. And in practice, there is a possibility of delivering...
متن کاملCompensator‐based intensity‐modulated radiation therapy for malignant pleural mesothelioma post extrapleural pneumonectomy
The present work investigated the potential of compensator-based intensity-modulated radiation therapy (CB-IMRT) as an alternative to multileaf collimator (MLC)-based intensity-modulated radiation therapy (IMRT) to treat malignant pleural mesothelioma (MPM) post extrapleural pneumonectomy. Treatment plans for 4 right-sided and 1 left-sided MPM post-surgery cases were generated using a commercia...
متن کامل