Automated determination of serum ceruloplasmin activity with o-dianisidine dihydrochloride as substrate.

نویسندگان

  • K H Schosinsky
  • H P Lehmann
  • M F Beeler
چکیده

An automated method for the enzymatic determination of ceruloplasmin with o-dianisidine dihydrochloride as substrate is described. The method enables the measurement of 30 samples per hour with a coefficient of variation (day-to-day) of 2.8%. Results correlate well (r equals 0.99 with those obtained by the corresponding manual method

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of ceruloplasmin from its oxidase activity in serum by use of o-dianisidine dihydrochloride.

We have developed a new method for determination of serum ceruloplasmin from its oxidase activity, in which o-dianisidine dihydrochioride is used as substrate. o-Dianisidine dihydrochloride is more stable than is the more widely used p-phenylenediamine substrate, and forms a stable product that is measured at 540 nm. Correlation was good between results of this method and those obtained with bo...

متن کامل

Standardization of serum ceruloplasmin concentrations in international enzyme units with o-dianisidine dihydrochloride as substrate.

We describe a method for calculating the absorptivity (in terms of substrate consumed) of the colored solution obtained when o-dianisidine dihydrochloride is oxidized by ceruloplasmin. By oxidizing o-dianisidine dihydrochloride with known amounts of hydrogen peroxide we could determine that the molar reacting ratio of o-dianisidine to hydrogen peroxide is 2:1. So calculated, absorptivity is 9.6...

متن کامل

Truncating mutations in the Wilson disease gene ATP7B are associated with very low serum ceruloplasmin oxidase activity and an early onset of Wilson disease

BACKGROUND Mutations in the gene ATP7B cause Wilson disease, a copper storage disorder with a high phenotypic and genetic heterogeneity. We aimed to evaluate whether 'severe' protein-truncating ATP7B mutations (SMs) are associated with low serum ceruloplasmin oxidase activities and an early age of onset when compared to missense mutations (MMs). METHODS The clinical phenotype of 59 geneticall...

متن کامل

Automated measurement of serum ferroxidase activity.

A method is described for automated measurement of serum ceruloplasmin ferroxidase activity. In this method, Fe2+ ions are used as the substrate. In addition, a new calibration system without ceruloplasmin is also presented. Optimum assay reaction conditions were determined. Maximal catalytic activity was obtained at 0.45 mol/L acetate buffer, pH 5.8. The reagents and calibrator are stable for ...

متن کامل

Automated determination of acid phosphatase.

A procedureis presentedfor the automated determination of acid phosphatase activity in biological materials from either plant or animal origin. The Technicon N-i flow diagram has been simplified, and the reagents for the measurement of enzymatically produced phenolic substanceshave been modified without lossof range or sensitivity. Both phenyiphosphateand a-naphthylphosphate, introduced by Babs...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 21 6  شماره 

صفحات  -

تاریخ انتشار 1975