ESR spectrometer with a loop-gap resonator for cw and time resolved studies in a superconducting magnet.
نویسندگان
چکیده
The design and performance of an electron spin resonance spectrometer operating at 3 and 9 GHz microwave frequencies combined with a 9-T superconducting magnet are described. The probehead contains a compact two-loop, one gap resonator, and is inside the variable temperature insert of the magnet enabling measurements in the 0-9T magnetic field and 1.5-400 K temperature range. The spectrometer allows studies on systems where resonance occurs at fields far above the g approximately 2 paramagnetic condition such as in antiferromagnets. The low quality factor of the resonator allows time resolved experiments such as, e.g., longitudinally detected ESR. We demonstrate the performance of the spectrometer on the NaNiO2 antiferromagnet, the MgB2 superconductor, and the RbC60 conducting alkaline fulleride polymer.
منابع مشابه
A 94 GHz EPR Spectrometer with Fabry-Perot Resonator
An EPR spectrometer is described working in the 94 GHz (W-band) frequency range. It comprises a Fabry-Perot type microwave resonator connected to a conventional microwave bridge, a phase lock loop for microwave frequency stabilization, and a superconducting magnet. The improved separation of W-band spectra from two sites with only slightly different ^-factors is demonstrated using an a-bromo ra...
متن کاملAnalytical Study of Optical Bi-Stability of a Single-Bus Resonator Based on InGaAs Micro-Ring Array
In this paper, for the first time to our knowledge, we investigate the optical bi-stability in a compact parallel array of micro- ring resonators with 5μm radius, induced by optical nonlinearity. Due to the nature of perfect light confinement, resonance and accumulation process in a ring resonator, optical nonlinear effects, even at small optical power of a few milliwatts in this structure are ...
متن کاملESR Spatiotemporal Measurement Using the Rapid Field Scan L-Band ESR-CT System for Determination of Rate Constants of Nitroxide Radical Reduction
The rate constants of nitroxide reduction by ascorbate ion were determined from a time-series measurement of ESR images, that is, ESR spatiotemporal images, which were measured with a rapid field scan L-band ESR-CT system. Two test tubes containing the phosphate buffer solutions of 3-carbamoyl-2,2,5,5-tetramethylpyrrolidin-l-yloxy (C-PROXYL) and ascorbate ion with different concentrations were ...
متن کاملDesign and Implementation of Digital Demodulator for Frequency Modulated CW Radar (RESEARCH NOTE)
Radar Signal Processing has been an interesting area of research for realization of programmable digital signal processor using VLSI design techniques. Digital Signal Processing (DSP) algorithms have been an integral design methodology for implementation of high speed application specific real-time systems especially for high resolution radar. CORDIC algorithm, in recent times, is turned out to...
متن کاملSuperconducting Microstrip-Fed Antenna Coupled to a Microwave Kinetic Inductance Detector
A proper antenna to couple to a microstrip Microwave Kinetic Inductance Detector (MKID) is designed and simulated. A twin-slot microstrip-fed inline antenna is designed for frequency band of 600-720~GHz integrated with an elliptical lens and coupled to the MKID. A systematic design procedure for design of such antenna with microstrip inline feeding is presented. Whole structure of lens and twin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance
دوره 173 2 شماره
صفحات -
تاریخ انتشار 2005