Large-Scale Non-Linear 3D Reconstruction Algorithms for Electrical Impedance Tomography of the Human Head

نویسندگان

  • L. Horesh
  • M. Schweiger
  • S. R. Arridge
چکیده

Non-linear image reconstruction methods are desirable for applications in electrical impedance tomography (EIT) such as brain or breast imaging where the assumptions of linearity are violated. We present a novel non-linear Newton-Krylov method for solving large-scale EIT inverse problems, which has the potential advantages of improved robustness and computational efficiency over previous methods. This combines Krylov-subspace efficiency in the production of an implicit Hessian inverse together with the Newton-type search direction effectiveness. The computational cost was assessed by comparing the objective function value and image error norm with respect to run-time, iteration count and memory consumption with six other non-linear methods, including Damped Newton-Gauss, Levenberg-Marquardt, Variable Metric and non-linear Conjugated Gradients, using realistic layered head models with meshes of 4, 12 and 31K elements. For the small-scale model, Newton-type methods slightly outperformed the Krylov-Newton approach, while the other large-scale methods performed poorly. For the larger two models, the Newton-Krylov approach converged much more rapidly than the Krylov-subspace and quasi-Newton methods; Newton-type methods failed to converge in the time available. This approach opens a new frontier for non-linear EIT image reconstruction, as it allows production of accurate solutions of large-scale realistic models using modest computational resources. Keywords— Large-scale, Newton-Krylov, Non-linear reconstruction, Monopolar sources

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Beyond the linear domain - The way forward in MFEIT image reconstruction of the human head

Multi-Frequency Electrical Impedance Tomography (MFEIT) is a promising technique for generating pseudo-absolute images of the head in conditions such as acute stroke, when a time referenced dynamic image is not possible. Unfortunately, the forward solution of EIT problem is non-linear and regional changes in admittivity of more than 50% with frequency exceed the linear domain. Linear solvers fa...

متن کامل

Process Compliant Electrical Impedance Instrumentation for Wide Scale Exploitation on Industrial Vessels

In order to apply electrical impedance (EIT), and other modalities, against industrial unit operations it is requisite to employ a sensor architecture which is compliant with the subject process such that it will not detrimentally effect its efficiency nor the integrity of the associated vessel structure. Traditionally symmetrical electrode architectures have been adopted for electrical tomogra...

متن کامل

Comparison of 3D Image Reconstruction Techniques using Real Electrical Impedance Measurement Data

The present status of electrical impedance tomography (EIT) is such that many successful laboratory based studies and pilot plant demonstrators are generating interest in developing the technology. However, while the EIT problem is inherently 3D, many studies make 2D assumptions in order to simplify the problem. Proportionately less work has been carried out on the true 3D EIT problem, outside ...

متن کامل

Using the GRID to improve the computation speed of electrical impedance tomography (EIT) reconstruction algorithms.

In our group at University College London, we have been developing electrical impedance tomography (EIT) of brain function. We have attempted to improve image quality by the use of realistic anatomical meshes and, more recently, non-linear reconstruction methods. Reconstruction with linear methods, with pre-processing, may take up to a few minutes per image for even detailed meshes. However, it...

متن کامل

Electrical Impedance Tomography for Geophysical Applications

We report on the development of a new software package for image reconstruction in threedimensional Electrical Impedance Tomography (EIT). Designed for large-scale computations, the software includes mesh generation utilities, a simulator of the quasi-static electrical potential fields based on finite elements and regularized inversion algorithms. We describe in brief some of its main functions...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006