Regarding the Quality of the Power Inserted into the Grid

نویسندگان

  • Samuel Vasconcelos Araújo
  • Alfred Engler
  • Fernando Luiz Marcelo Antunes
چکیده

This paper deals with the analysis, design and optimization of a LCL filter topology to connect a 7MW NPC inverter to the grid. Following the requirements based on the IEEE 519-1992 recommendation and the German Guideline VDEW, simulation results were evaluated in order to access the performance of the proposed filter and the quality of the current injected into the grid.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An LCL-filtered Single-phase Multilevel Inverter for Grid Integration of PV Systems

Integration of the PV into the electrical grid needs power electronic interface. This power electronic interface should have some key features and should come up with grid codes. One of the important criteria is the quality and harmonic contents of the current being injected to the grid. High-order harmonics of the grid current should be very limited (lower than 0.3% of the fundamental current)...

متن کامل

Improving the Voltage Profile of the Power System Using PV-STATCOM

This paper presents a novel concept of utilizing the photo voltaic solar farm inverter as STATCOM(Static Compensator), named PV-STATCOM, in order to improve the voltage profile of the power system. The entire STATCOM is able to transmit either active or reactive power into the grid. This system is connected to a 14 BUS IEEE standard grid as a case study to simulate the performance of the system...

متن کامل

Enhancement of Power Quality in Grid Integrated System using DC-link Voltage PI Controlled VSC based Statcom

This paper demonstrates an enhancement of power quality in grid integrated systems with the help of the proposed control strategy for voltage source converter based active power filters. The Shunt Active Power filters (SAPF) are extensively utilized in modern grid integrated systems to diminish the power quality concerns associated with it. The SAPF is one of the various power filters, which ha...

متن کامل

A New High Frequency Grid Impedance Estimation Technique for the Frequency Range of 2 to150 kHz

Grid impedance estimation is used in many power system applications such as grid connected renewable energy systems and power quality analysis of smart grids. The grid impedance estimation techniques based on signal injection uses Ohm’s law for the estimation. In these methods, one or several signal(s) is (are) injected to Point of Common Coupling (PCC). Then the current through and voltage of ...

متن کامل

Power Quality Improvement in Traction Power Supply Networks

AC railway traction loads are usually huge single phase loads. As a result, a significant amount of Negative Sequence Current (NSC) is injected into utility grid. Moreover, harmonics and consumption ofreactive power are further power quality problems that the supply network is encountering. In this paper, acompensation strategy with the aid of Railway Power Conditioner (RPC) is proposed to over...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007