Reader's Forum
نویسندگان
چکیده
Could the authors provide the rationale of choosing the two different contaminants, blood and the blood stopper agent used in group I and II, respectively? Q2. I believe that the damages done on the resin tags during application of blood with a brush have something to do with the result of the group I associated with the lowest shear bonding stress (SBS) values. Q3. The moisture and temperature in the oral envi ron ment have significant influence on bond failure. There fore, it could have been better if the teeth were treated in the circumstances similar to the actual oral conditions before the SBS test. Q4. Did any of the teeth require acid etching twice or more before getting the frosty white appearance? If yes, how could the multiple acid etching procedure affect the shear bond strength level? We thank author(s) for his interest in our article and for the comments and matters he raised. You can find the answers below. A1. Contamination by blood and blood stopper agent occurs in different ways during bonding ortho dontic buttons on impacted teeth. Blood conta mination is mainly caused by a leakage from the close surrounding tissues while blood stopper conta mination occurs from its direct application on the teeth as spray or drop. To simulate these conditions we had decided to apply these materials as described. A2. That is a valid point. However, extra care has been taken so that only gentle nondisruptive man ners were used throughout the procedure. Though it is difficult to prove, it can be assured that there should be so little to no damage added on resin tags during the brushing step. A3. I am agree with this comment. However, I also believe that primary bond strength is equally, if not more, important factor to be considered in bonding on impacted teeth, and as such no heat cycles was necessary in this study. A4. Fortunately, none of the teeth were in need of repeated acid etching before the chalky white frosty appearance. Obviously, if multiple acid etching steps were used, it could have influenced the shear bond strength in a negative way. Effects of contamination by either blood or a hemostatic agent on the shear bond strength of orthodontic buttons. which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
منابع مشابه
Reader's Forum
as I find this study provides important answers to what many orthodontists have asked. Since miniscrews became an integral part of contemporary orthodontic practice, some of failed miniscrews have been re-sued for various reasons. Yet, up to date, there is no firmly agreed consensus in our profession regarding this area, and this investigation attempts to show how the relevant factors come into...
متن کاملReader's Forum
Q3. As the result, there were statistically signifi cant differences in the 7 angular and 5 linear measurements between the 2D and 3D analysis. However, you also described no clinically significant difference between them in the discussion and conclusion sections. Would you be so kind as to explain the reasons to lead to this conclusion? Q4. Many studies, including this study, have focused on a...
متن کاملReader's Forum
Questioned by Hyub-Soo Lee Private Practice, Daejeon, Korea A1. In the past literature review, the relationship between smile esthetic variables and malocclusion lacked solid and sufficient evidence, therefore it aroused our interest to design a study of analyzing smile characteristics in different malocclusions. In our study, we found that arc ratio, upper teeth number showing, upper lip heigh...
متن کاملReader's Forum
Q3. What do the authors think about the influence of surgical methods (one-jaw or two-jaw surgeries, osteotomy design, and so on), the amount of bony change by the surgery, and post surgical orthodontic treatment on the results of the study? Q4. The authors mentioned that the patients underwent plate removal operation at 6 months after the surgery, and they also discussed about the possibility ...
متن کاملاثربخشی تبلیغ طرحهای کتابخوانی نهاد کتابخانههای عمومی کشور بر جذب مخاطب از نظر اعضای کتابخانه: مطالعۀ موردی کتابخانههای عمومی استان زنجان
Purpose: The present research aims to investigate the advertising effectiveness of Iran Public Libraries Foundation's reading projects in attracting users to the public libraries of Zanjan province from the viewpoint of their members. Methodology: This is an applied and survey-descriptive research whose statistical population includes 33 users (i.e. patrons) who were members of public librarie...
متن کاملReader's Forum
A1. The temporary skeletal anchorage device used in this study, C-implant, requires higher removal torque compared to other orthodontic mini-implants because of its greater osseointegration potential. It also means that the C-implant allows application of multi-directional force system such as retraction combined with intrusion by concurrent use of intraand intermaxillary elastics. In such case...
متن کامل