Quadrature Errors and DC Offsets Calibration of Analog Complex Cross-Correlator for Interferometric Passive Millimeter-Wave Imaging Applications
نویسندگان
چکیده
The design and calibration of the cross-correlator are crucial issues for interferometric imaging systems. In this paper, an analog complex cross-correlator with output DC offsets and amplitudes calibration capability is proposed for interferometric passive millimeter-wave security sensing applications. By employing digital potentiometers in the low frequency amplification circuits of the correlator, the outputs characteristics of the correlator could be digitally controlled. A measurement system and a corresponding calibration scheme were developed in order to eliminate the output DC offsets and the quadrature amplitude error between the in-phase and the quadrature correlating subunits of the complex correlator. By using vector modulators to provide phase controllable correlated noise signals, the measurement system was capable of obtaining the output correlation circle of the correlator. When injected with -18 dBm correlated noise signals, the calibrated quadrature amplitude error was 0.041 dB and the calibrated DC offsets were under 26 mV, which was only 7.1% of the uncalibrated value. Furthermore, we also described a quadrature errors calibration algorithm in order to estimate the quadrature phase error and in order to improve the output phase accuracy of the correlator. After applying this calibration, we were able to reduce the output phase error of the correlator to 0.3°.
منابع مشابه
A Passive Millimeter-wave Imager Used for Concealed Weapon Detection
An 8mm-band passive millimeter-wave imager BHU-2D has been developed by Beihang University. This imager is designed for detecting concealed weapons on human body. The imager adopts two-dimensional synthetic aperture interferometric radiometer (SAIR) technique which avoids the radiation risk to human body. Compared with scanning technique, SAIR technique could obtain images of a larger field of ...
متن کاملDigital I/Q Demodulator
I/Q demodulation is a common and useful RF signal processing technique used in charged-particle accelerators. When implemented with conventional analog RF components, a number of inherent errors can degrade the I/Q Demodulator performance, including gain balance, quadrature-phase balance, DC offsets, impedance match, and carrier leakage. Recent advances in high-speed analog-to-digital converter...
متن کاملDigital I/Q Demodulator* SLAC-PUB-95-6857
I/Q demodulation is a common and useful RF signal processing technique used in charged-particle accelerators. When implemented with conventional analog RF components, a number of inherent errors can degrade the I/Q Demodulator performance, including gain balance, quadrature-phase balance, DC offsets, impedance match, and carrier leakage. Recent advances in high-speed analog-to-digital converter...
متن کاملGallium Phosphide IMPATT Sources for Millimeter-Wave Applications
The potentiality of millimter-wave (mm-wave) double-drift region (DDR) impact avalanche transit time (IMPATT) diodes based on a wide bandgap (WBG) semiconductor material, Gallium Phosphide (GaP) has been explored in this paper. A non-sinusoidal voltage excited (NSVE) large-signal simulation method has been used to study the DC and high frequency characteristics of DDR GaP IMPATTs dsigned to ope...
متن کاملKalman filter based calibration of precision motion control
A method is described and validated for the automatic calibration of analog sine-wave quadrature sensors, such as optical encoders, embedded in a functioning system. The algorithm uses a Kalman filter to estimate the true position of the direct-drive actuated joint using a model of it's dynamics, an applied actuator command, and measurements from the uncalibrated sensor. From the estimated true...