Anesthesia machine breathing tube holder

نویسندگان

  • A Ram Doo
  • Sang-Kyi Lee
چکیده

dotracheal tube and are composed of inspiratory and expiratory corrugated limbs. The two breathing tubes carry respiratory gases with volatile anesthetics to and from patients during general anesthesia. Although longer corrugated breathing tubes allow the anesthesia machine to be located farther from the patients, they are so long and flexible that they tend to hang down below the operating table and strain the endotracheal tube. When the breathing circuit system is interrupted due to disconnection of the elbow connector or Y-piece connector or due to a kinked tracheal tube, a dangerous ventilation failure may result. Breathing tube holders may help to avoid these accidents. Various commercially available breathing tube holders are used for this purpose increasingly commonly, but it is the authors’ opinion that they have some drawbacks along with their advantages. Breathing tubes can easily become unattached from conventional breathing tube holders, because the grooves for the tubes are too shallow and opened too wide. We have devised a new design of breathing tube holder that improves practicality, stability and portability (Fig. 1). The “L”shaped breathing tube holder, which can be made of either metal materials such as stainlesssteel or aluminum or acryl, comprises two right-angled limbs (15 cm wide and 35 cm long for the long limb and 15 cm wide and 25 cm long for the short limb). One limb is used as a supporting plate inserted beneath the patient’s pillow or operation table mattress, and the other holds the breathing tube. The large grooves on the top and sides of the device support and organize the corrugated breathing tubes, and numerous small clefts hold intravenous fluid lines or the gas sampling line. The first advantage of the device is practicality. The lengths of the two limbs of the device are different so as to be applicable to both adults and pediatrics; the longer tube holding limb for adults can be switched to the supporting limb when used for pediatrics. Second, to achieve greater stability, the grooves on the top have narrow openings with widths similar to the outer diameter of the single breathing tube. The breathing tubes may be placed securely without being pulled out of the grooves after being inserted one after another. Also, the right angle of the lateral grooves improves stability. Finally, our device has the adLetter to the Editor

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

To reuse your circuit: The HME debate, AANA Journal, October 1999

have been used for more than 30 years for heat and moisture retention during general anesthesia. Studies about bacteriostatic vs nonbacteriostatic HMEs (BHMEs/ NHMEs) have been conducted to assess their role in preventing bacterial transmission to the anesthesia breathing circuit; none have been done on anesthetized patients in the operating room. The present study adds to existing knowledge ab...

متن کامل

Interruption in the supply of breathing gas during general anesthesia due to malposition of the vaporizer -A case report-

We report a case of interruption in the supply of breathing gas during general anesthesia caused by malposition of the Drager Vapor 2000® vaporizer, which was accidentally tilted and lifted off the Selectatec manifold of the anesthesia machine. Because the patient was an 1-month-old infant, we couldn't check if he had experienced awareness with recall. We emphasize the importance of checking th...

متن کامل

Expiratory limb ventilation during unique failure of the anesthesia machine breathing circuit.

751 March 2013 T anesthesia machine is the most integral piece of equipment used by anesthesia providers. When semiclosed circle systems are used, unidirectional valves become integral components that direct carbon dioxide containing gas across the absorbent and along the inspiratory limb, mixing with fresh gas as it flows into the patient. Unfortunately, human error is known to be the most com...

متن کامل

Esophageal aspiration of air through the drain tube of the ProSeal laryngeal mask.

IMPLICATIONS Two patients experienced partial upper airway obstruction while breathing spontaneously with the ProSeal laryngeal mask airway. This resulted in esophageal aspiration of air through the drain tube.

متن کامل

Models for an Anesthesia Breathing Circuit

This paper presents a mathematical model of a semi-closed anesthesia breathing circuit. The model comprises four perfect-mixing compartments (corresponding to the lung, the reservoir bag, and the two absorber cannisters), together with four tubes through which gas flows without mixing (corresponding to the inspiratory tube, the expiratory tube, the arm leading to the reservoir bag, and the anat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 68  شماره 

صفحات  -

تاریخ انتشار 2015