Ocular lens does not change volume during accommodation.
نویسندگان
چکیده
where d is the distance between the center of masses of the two symmetrical halves of the CSAs. Critical to the use of this theorem is the determination of the exact center of mass of each CSA (6, 7). The authors did not specify how the center of mass was determined nor the accuracy, precision, and variation of this measurement in the bovine lens. There are additional significant deficiencies with the design and execution of the authors’ study. First, to support the bovine lens the authors used cyanoacrylate glue to attach the iris and ciliary body to a rubber washer. The authors did not control for the effects of the fumes generated by the cyanoacrylate glue (3) on the shape and permeability of the bovine lens capsule. Second, they state: “the visual axis of the photographic camera was on a perpendicular plane with respect to the A-P axis of the lens; validated by determining that the two CSAs were symmetrically identical and that each CSA was a minimum.” The fallacy in this approach can be appreciated by noting that simple rotation of the lens around its equatorial axis would cause the CSA to minify and remain symmetrically identical. Three-dimensional, positional references are needed to provide a reliable way of ensuring that the lens did not rotate between photographs. Third, since the ciliary body and expandable ring were completely intact around the entire circumference of the bovine lens equator, it is not apparent how the authors were able to image the complete profile of the lens through just the aperture of the supporting aluminum plate (see Fig. 3 in Gerometta et al.). Did the authors interpolate the position of the bovine lens equator where its edge was blocked by the ciliary body and the expandable ring? Fourth, the cross-sectional profile of the relaxed (accommodated) in vitro bovine lens shown in their Fig. 4 (reproduced herein in as Fig. 1) does not demonstrate the flattening of the peripheral anterior surface of the lens that has been observed during human in vivo accommodation by the reflection of light from the anterior surface of the lens (4, 14), Scheimflug photography (2), and optical coherence tomography (OCT) (9). The authors images actually demonstrate the opposite of the in vivo observations (Fig. 3 in Ref. 5), confirming that their experiments are not representative of in vivo accommodation. Fifth, the authors’ used dimensional data given by Rosen et al. (10) to predict volume changes of in vitro human lenses. A subsequent study by members of this same group (1) demonstrated that Rosen’s et al. (10) data were unreliable. They indicated that to assess whether measurements of in vitro lenses are correct, it is necessary “to determine if swelling has taken place before acceptance of data” (1). Gerometta et al. (5) did not meet this prerequisite for their bovine lens study and used Rosen’s et al. (10) faulty human lens data. Finally, the authors used the magnetic resonance imaging studies of Strenk et al. (12, 13) to support their calculations. The Strenk et al. (12, 13) studies failed to incorporate the essential positional references required to demonstrate image correspondence before making their measurements (8), and their calculations of lenticular CSA were, consequentially, unreliable (6, 11). Because of the above deficiencies, the authors’ study does not provide any reliable information concerning volume change of the lens with accommodation. Conclusions concerning the mechanism of accommodation cannot be based on this study.
منابع مشابه
Volume change of the ocular lens during accommodation.
During accommodation, mammalian lenses change shape from a rounder configuration (near focusing) to a flatter one (distance focusing). Thus the lens must have the capacity to change its volume, capsular surface area, or both. Because lens topology is similar to a torus, we developed an approach that allows volume determination from the lens cross-sectional area (CSA). The CSA was obtained from ...
متن کاملDevelopment of an Accommodation-Dependent Eye Model and Studying the Effects of Accommodation on Electron and Proton Dose Conversion Coefficients
Introduction International Commission on Radiological Protection (ICRP) has provided a comprehensive discussion on threshold dose for radiation-induced cataract in ICRP publication 116. Accordingly, various parts of the eye lens have different radio-sensitivities. Recently, some studies have been performed to develop a realistic eye model with the aim of providing accurate estimation of fluence...
متن کاملA geometric model of ocular accommodation
An exoteric geometric mechanics model of ocular accommodation is detailed to elucidate the main ideas of various ongoing modeling efforts. The present study derives solutions for the stretched state of the ocular lens as it might appear during accommodation by using simple geometric arguments and a volume constraint, rather than the more mathematically intensive theory of elasticity. Results sh...
متن کاملOcular anterior segment biometry and high-order wavefront aberrations during accommodation.
PURPOSE We investigated the relationships between the ocular anterior segment biometry and the ocular high-order aberrations (HOAs) during accommodation by combined ultralong scan depth optical coherence tomography (UL-OCT) and wavefront sensor. METHODS We enrolled 35 right eyes of young healthy subjects (21 women and 14 men; age, 25.6 ± 3.1 years; spherical equivalent refractive error, -0.41...
متن کاملSurface change of the mammalian lens during accommodation.
Classical theories suggest that the surface area of the crystalline lens changes during accommodation while the lens volume remains constant. Our recent work challenged this view by showing that the lens volume decreases as the lens flattens during unaccommodation. In this paper we investigate 1) the magnitude of changes in the surface of the in vitro isolated cow lens during simulated accommod...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Cell physiology
دوره 293 5 شماره
صفحات -
تاریخ انتشار 2007