Development and validation of the Cozart DDS oral fluid collection device.

نویسندگان

  • T Speedy
  • D Baldwin
  • G Jowett
  • M Gallina
  • A Jehanli
چکیده

The testing of oral fluid for drugs of abuse has increased significantly over recent years and is now commonplace in drug rehabilitation clinics, the workplace, prisons and custody suites. The global problem of identifying drugged drivers has also led to an increase in oral fluid testing at the roadside. The main requirements for the implementation of roadside drug testing are a rapid sample collection time, collection of a known sample volume and recovery of drugs from the collection device. We report here the development of the Cozart DDS oral fluid collector, an oral fluid collector that combines rapid and adequate sample collection with satisfactory drug recovery. Oral fluid was collected from drug users (n=134) and drug-free individuals (n=137), using the Cozart DDS oral fluid collector. The mean time for the completion of collection (full coloration of the sample presence indicator) was 34 s for drug-free individuals and 44 s for drug users. The average volume collected was 0.34 mL (n=271). No chemical stimulant (to induce salivation) was used to achieve the collection times observed in either the drug-free or the drug-taking sample populations. Drugs were extracted from the collector using the Cozart DDS buffer and drug recovery was determined by Cozart enzyme immunoassays. The recovery studies showed that for amphetamine, Delta(9)THC, cocaine, methadone, methamphetamine, morphine and temazepam over 90% of the drug in the sample was eluted from the collector. The Cozart DDS oral fluid collector provides a reliable mechanism for the collection of oral fluid at the roadside that achieves the rapid collection times required.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of the Cozart Amphetamine Microplate EIA for the analysis of amphetamines in oral fluid.

The purpose of this study was to determine the performance characteristics of the Cozart Amphetamine Microplate EIA for detecting amphetamine in oral fluid. Oral fluid samples were collected using the Cozart RapiScan Collection System from 135 volunteer donors from drug treatment clinics. A further 35 oral fluid samples were collected from volunteer donors who were not drug users. The samples w...

متن کامل

Analytical evaluation of four on-site oral fluid drug testing devices.

The use of oral fluid (OF) as an alternative matrix for the detection of drugs of abuse has increased over the last decade, leading to the need for a rapid, simple, and reliable on-site OF testing device. Four on-site OF drug testing devices (Dräger DrugTest 5000, Cozart DDS, Mavand Rapid STAT, and Innovacon OrAlert) were evaluated on 408 volunteers at drug treatment centers. UPLC-MS-MS results...

متن کامل

The validation of one halitosis measuring device (Etiquette checker)‎

BACKGROUND AND AIM: Various measurement devices are available for detection of halitosis. For epidemiologic studies, it is necessary to use a portable and small device. This study aimed to investigation of correlation between measuring the device (Etiquette checker) with Halimeter. METHODS: One hundred volunteers (students and patients) participated in this study. The amount of volatile sulfur ...

متن کامل

Drug testing in oral fluid-evaluation of sample collection devices.

Nine different oral fluid (OF) collection devices were studied to evaluate their suitability for collecting samples for drug analysis. The devices were Greiner Bio-One, Orasure Intercept, Immunalysis Quantisal, StatSure Saliva.Sampler, Cozart, Sarstedt Salivette, Malvern Medical OraCol, Acro Biotech Salicule, and Varian OraTube. For comparison, OF was also collected into plastic tubes. The volu...

متن کامل

Development and validation of ELISA and GC-MS procedures for the quantification of dextromethorphan and its main metabolite dextrorphan in urine and oral fluid.

The development of a highly sensitive enzyme-linked immunosorbent assay and gas chromatography-mass spectrometry confirmation method for the detection of dextromethorphan and its major metabolite dextrorphan in urine and oral fluid is described. For the screening assay, the intraday precision was less than 8% for urine and less than 5% for oral fluid. The interday precision was less than 10% fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Forensic science international

دوره 170 2-3  شماره 

صفحات  -

تاریخ انتشار 2007