Simultaneous determination of polybrominated diphenyl ethers and polychlorinated biphenyls by gas chromatography-tandem mass spectrometry in human serum and plasma.

نویسندگان

  • Yan-ping Lin
  • Isaac N Pessah
  • Birgit Puschner
چکیده

Sensitive and reliable methods for simultaneous determination of polybrominated diphenyl ethers (PBDEs) and polychlorinated biphenyls (PCBs) in limited volumes of human serum or plasma need to be further documented especially when they accumulate at low levels that are still capable of disrupting endocrine and immune functions, and affecting neurodevelopment and reproduction. The objective of this study was to develop and validate a sensitive and quantitative method that simultaneously quantifies PBDEs and PCBs in 0.5 ml of human serum or plasma. We optimized a solid-phase extraction (SPE) method and used silica particle purification for the extraction of PBDEs and PCBs. Two multiple reactions monitoring (MRM) transitions were optimized for each congener. The sum of the transitions was used for quantification, and their abundance ratios were used for identification. The combined method optimization techniques resulted in limits of detection from 3 to 145 pg/ml for 10 PBDEs and 1-12 pg/ml for 15 PCBs. Method was solidly validated by analyzing serum fortified with a certified PBDE and PCB standard mixture from the National Institute of Standards and Technology (NIST). The accuracy was 88-118% and day-to-day precision was within 19%. The method was successfully applied to quantify native concentrations of PBDE and PCB in commercially available human serum. The sensitivity and selectivity of the GC/EI-MS/MS analysis enables it to be the method of choice for investigations of exposures to PBDE and PCB congeners, especially when sample volume is limited.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and application of a simplified clean-up procedure for the determination of polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) in horse fat by gas chromatography-tandem mass spectrometry (GC-MS/MS).

A simplified clean-up procedure was developed in combination with gas chromatography-tandem mass spectrometry (GC-MS/MS) for the determination of polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) in adipose tissue. Clean-up was performed by the successive application of a Mega Bond Elut silica column and a Bond Elut PCB column. Validation of the method was conducted ac...

متن کامل

Comparison of polybrominated diphenyl ethers (PBDEs) and polychlorinated biphenyls (PCBs) in the serum of hypothyroxinemic and euthyroid dogs

OBJECTIVE To determine the profile of 14 polybrominated diphenyl ethers (PBDEs) and 23 polychlorinated biphenyls (PCBs) in serum of domestic canines and whether this was predictive of thyroid hormone status. SAMPLES Serum samples were collected from 51 client-owned dogs visiting the University of California Davis William R. Pritchard Veterinary Medical Teaching Hospital during 2012 to 2016 fo...

متن کامل

Method development for the analysis of polybrominated diphenyl ethers, polychlorinated biphenyls, polychlorinated dibenzo-p-dioxins and dibenzo-furans in single extract of sediment samples.

A comprehensive method was developed for quantitative analysis of polybrominated diphenyl ethers (PBDEs), polychlorinated biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins and dibenzo-furans (PCDD/Fs) in one single extract of environmental samples. The sample preparation procedure included two fractionation steps using silver nitrate silica chromatography to separate PBDEs from PCBs and PC...

متن کامل

Determination of polybrominated diphenyl ethers and polychlorinated biphenyls in human adipose tissue by large-volume injection-narrow-bore capillary gas chromatography/electron impact low-resolution mass spectrometry.

A new analytical method has been developed for the quantification of polybrominated diphenyl ethers (PBDEs) in human adipose tissue samples. After Soxhlet extraction and a cleanup procedure using two successive solid-phase extraction cartridges containing acid silica and acid silica: neutral silica:deactivated basic alumina (from top to bottom), detection can been achieved by narrow-bore (0.10-...

متن کامل

Quantification of Polychlorinated Biphenyls and Polybrominated Diphenyl Ethers in Commercial Cows’ Milk from California by Gas Chromatography–Triple Quadruple Mass Spectrometry

We determined 12 polybrominated diphenyl ethers (PBDEs) and 19 polychlorinated biphenyls (PCBs) congeners in eight different brands of commercial whole milk (WM) and fat free milk (FFM) produced and distributed in California. Congeners were extracted using a modified quick, easy, cheap, effective, rugged and safe (QuEChERS) method, purified by gel permeation chromatography, and quantified using...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 113  شماره 

صفحات  -

تاریخ انتشار 2013