High Resolution T2 Breast Imaging using FADE
نویسندگان
چکیده
Introduction High-resolution 3D imaging is useful for improving the specificity of breast MRI since morphological characteristics, such as spiculations and heterogeneity, vary with histology [1]. The specificity of breast MRI can be further improved by considering physiological information such as diffusion [2]. Unlike T1-weighted contrast-enhanced imaging, it is difficult to acquire high-resolution T2 and diffusion-weighed images in reasonable scan times due to SNR and SAR limitations. We evaluate a simple, fast, 3D sequence that can provide information about T2 and diffusion for breast imaging. Theory The FADE (fast acquisition double echo) sequence [3] (also known as DESS and MENSA) consists of a steady-state imaging sequence with a second readout following spoiler gradients, which can be played on any axis (Figure 1). The gradient applied between the two acquisitions causes the FID to be dephased before the SSFP-Echo and then refocused for the SSFP-Echo acquisition of later TRs. The SSFP-FID has higher SNR and the SSFP-Echo is heavily T2-weighted [3]. In addition to rephasing the signal for the SSFPEcho, the spoilers also provide some diffusion weighting; the strength of the diffusion weighting increases with gradient area and TR. Methods & Results We scanned two patients at 3T using the FADE sequence (TE2=47ms, TR=30ms, 30° flip angle, spatial-spectral excitation, 2:38 scan time) with a spoiler area of 8000 Gμs/cm on the L/R axis (the direction of smallest expected motion), parallel imaging in the L/R direction, and an eight-channel breast coil. We acquired 28 3-mm axial slices with a 30×30cm FOV and 0.8×1.2m resolution in-plane. For comparison, we show MIP images from the T2-weighted diagnostic scan (TE/TR=106/5000ms, ETL 16, 1.1×1.3mm resolution in-plane, 5mm slices). The SSFP-Echo MIP image from the FADE acquisition shows contrast similar to that of the T2-weighted image (Figure 2). Lymph nodes and cysts (small arrow) appear bright on both images. It is interesting to note that blood vessels visible in the T2-weighted image do not appear in the SSFP-Echo image (large arrow). To study the effects of T2 and diffusion on the signal in the two echoes, we imaged water (long T2/high diffusion) and oil and gel (both with short T2/low diffusion) using spoiler gradients of 8000 and 4000Gμs/cm. The SSFP-Echo signal is affected by both T2 decay and diffusion [4]. Species with shorter T2 experience a larger signal decrease between the two echoes (large arrow). Tissues with higher diffusion have lower signal when a larger crusher is played (small arrow). Discussion The FADE sequence allows the acquisition of high-resolution, 3D T2weighted images in a short scan time with low SAR. While the relationship between diffusion, sequence parameters, and signal intensity is complicated [4], we are able to generate images with diffusion weighting, as evidenced by the lack of signal from the blood vessels. Since tumors with high cellular density have less diffusion than healthy tissues, we expect a larger signal decrease between the two echoes in healthy tissue than in tumors. By acquiring images with different gradient areas, we can further distinguish the effects of T2 and diffusion. Although motion can degrade the quality of diffusion-weighted images, the patient data shows that we are able generate diagnostically useful images of the breast in spite of bulk, respiratory, and cardiac motion. Conclusion We have found that FADE (DESS/MENSA) is potentially useful for breast imaging as it is sensitive to both T2 and diffusion and, thus, may help distinguish benign and malignant lesions. SSFP-Echo MIP T2-weighted MIP Figure 1 FADE Sequence Diagram
منابع مشابه
Prospective Motion Correction for T2- and Diffusion-Weighted Breast Imaging with FADE
Introduction T2and diffusion-weighted imaging are useful as non-contrast-enhanced MRI techniques; however both are limited by low-resolution and blurring [1,2]. The Fast Acquisition Double Echo (FADE) sequence is a 3D steady-state sequence with two echoes per TR; spoiler gradients that separate the echoes provide diffusion weighting. FADE enables high-resolution T2and diffusion-weighting imagin...
متن کاملUltrafast near-isotropic spatial resolution 3D balanced-SSFP Dixon imaging in the breast
INTRODUCTION: T2 imaging in the breast is most commonly performed using a fat suppressed 2D Fast Spin Echo (FSE) pulse sequence. The in-plane spatial resolution is high (<1mm) but the 3-4 mm slice thickness blurs fine structures and makes multi-planar reformatting sub-optimal. Balanced steady-state free precession (b-SSFP) techniques yield high SNR images in short scan times with a T2-like (T2/...
متن کاملIn vitro Study of SPIONs-C595 as Molecular Imaging Probe for Specific Breast Cancer (MCF-7) Cells Detection
Background: Magnetic resonance imaging (MRI) plays an essential role in molecular imaging by delivering the contrast agent into targeted cancer cells. The aim of this study was to evaluate the C595 monoclonal antibody-conjugated superparamagnetic iron oxide nanoparticles (SPIONs-C595) for the detection of breast cancer cell (MCF-7). Methods: The conjugation of monoclonal antibody and nanopartic...
متن کاملDuctal carcinoma in situ: magnetic resonance and ultrasound imaging in mouse models of breast cancer
The earliest stage of breast cancer, ductal carcinoma in situ (DCIS), is a remarkably heterogeneous disease with diverse molecular and prognostic subtypes. Mouse models of breast cancer offer an effective experimental framework in which to investigate DCIS, and biomedical imaging can provide potential insights into the biology of these models. In this study, we develop a high resolution, multi-...
متن کاملBreast MRI Using a Balanced Steady-State Free Precession Imaging with a Two-Point Dixon Fat-Water Reconstruction Algorithm: Preliminary Experience and Comparison with 2D FSE
INTRODUCTION: Balanced steady-state free precession (b-SSFP) techniques yielding high SNR images in short scan times with T2-like image contrast have several appealing attributes for clinical breast MRI [1]. Clinical T2 imaging in the breast is routinely performed using a fat suppressed 2D Fast Spin Echo (FSE) pulse sequence with high in-plane spatial resolution. The 3-5 mm slice thickness obsc...
متن کامل