The Relative Performance of NDIR-based Sensors in the Near Real-time Analysis of CO2 in Air
نویسندگان
چکیده
In this study, the reliability of NDIR-based sensors was explored by evaluatingthe comparability between measurement systems in the near real-time analysis of CO₂. Forthis purpose, replicate analyses were performed using sensors of two different model types(H-550 and B-530, ELT Company, Korea). Three replicate data of each sensor typecollected continuously by side-by-side analysis in three second intervals (a duration of 304hour) were evaluated for the relative performance of NDIR sensors. The reproducibility ofsensors, when assessed by relative standard error (RSE %) values of all sensor units,showed moderate changes with time with the overall mean of 2.33%. When CO₂measurements from all NDIR sensor units were evaluated by correlation analysis, theresults showed strong comparability, regardless of the model type. The overall results ofthis study suggest that NDIR sensors are reliable enough to produce highly comparabledata at least in a relative sense.
منابع مشابه
Use of a Dynamic Enclosure Approach to Test the Accuracy of the NDIR Sensor: Evaluation Based on the CO2 Equilibration Pattern
As part of a quality assurance (QA) study for sensor systems, an enclosureapproach is applied to assess the accuracy of non-dispersive infrared (NDIR)-based CO₂sensors. To examine the performance of the sensor system, an enclosure chambercontaining six sensor units of the two model types (B-530 and H-500) was equilibratedwith calibrated CO₂ standards at varying concentration levels. Initially, ...
متن کاملLab and Field Scale Modeling of Near Miscible CO2 Injection in Different Porous Mediums
The main purpose of this investigation is to study the effect of near miscible CO2 injection in different porous mediums on both lab and field scales. This effect can be traced by the change of two-phase gas-oil relative permeability curves. In this work, the experiments have been performed on three rock types (i.e. sandstone, dolomite, and artificial fractured sandstone) based on an incrementa...
متن کاملNDIR Gas Sensor for Spatial Monitoring of Carbon Dioxide Concentrations in Naturally Ventilated Livestock Buildings
The tracer gas ratio method, using CO2 as natural tracer, has been suggested as a pragmatic option to measure emissions from naturally ventilated (NV) barns without the need to directly estimate the ventilation rate. The aim of this research was to assess the performance of a low-cost Non-Dispersive Infra-Red (NDIR) sensor for intensive spatial field monitoring of CO2 concentrations in a NV dai...
متن کاملA Novel Solid State Non-Dispersive Infrared CO2 Gas Sensor Compatible with Wireless and Portable Deployment
This paper describes development of a novel mid-infrared light emitting diode (LED) and photodiode (PD) light source/detector combination and use within a non-dispersive infrared (NDIR) carbon dioxide gas sensor. The LED/PD based NDIR sensor provides fast stabilisation time (time required to turn on the sensor from cold, warm up, take and report a measurement, and power down again ≈1 second), l...
متن کاملDetection of Fuel Adulteration in Real Time Using Optical Fiber Sensor and Peripheral Interface Controller
Detection of fuel adulteration in real time is the most important need of the world as it generates the hazardous effects on the environment, living and nonliving things. Various automotive users and fuel providers may mix kerosene in petrol and diesel. Adulterated fuel increases air pollution, as well as reduces the performance of vehicle engines. Such a malpractice in fuel is prevailing becau...
متن کامل