Tandem Spinach Array for mRNA Imaging in Living Bacterial Cells.

نویسندگان

  • Jichuan Zhang
  • Jingyi Fei
  • Benjamin J Leslie
  • Kyu Young Han
  • Thomas E Kuhlman
  • Taekjip Ha
چکیده

Live cell RNA imaging using genetically encoded fluorescent labels is an important tool for monitoring RNA activities. A recently reported RNA aptamer-fluorogen system, the Spinach, in which an RNA aptamer binds and induces the fluorescence of a GFP-like 3,5-difluoro-4-hydroxybenzylidene imidazolinone (DFHBI) ligand, can be readily tagged to the RNA of interest. Although the aptamer-fluorogen system is sufficient for imaging highly abundant non-coding RNAs (tRNAs, rRNAs, etc.), it performs poorly for mRNA imaging due to low brightness. In addition, whether the aptamer-fluorogen system may perturb the native RNA characteristics has not been systematically characterized at the levels of RNA transcription, translation and degradation. To increase the brightness of these aptamer-fluorogen systems, we constructed and tested tandem arrays containing multiple Spinach aptamers (8-64 aptamer repeats). Such arrays enhanced the brightness of the tagged mRNA molecules by up to ~17 fold in living cells. Strong laser excitation with pulsed illumination further increased the imaging sensitivity of Spinach array-tagged RNAs. Moreover, transcriptional fusion to the Spinach array did not affect mRNA transcription, translation or degradation, indicating that aptamer arrays might be a generalizable labeling method for high-performance and low-perturbation live cell RNA imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Spinach Hydro-alcoholic Extract on Resistin mRNA Expression in Visceral Adipose Tissue of Rats Exposed to Chronic Restraint Stress

Introduction: Resistin is a peptide hormone, secreted by adipose tissue. Increased secretion of resistin results in insulin resistance and metabolic syndrome. The aim of this study was to determine the effect of hydro-alcoholic spinach (Spinacia oleraceae L.) extract on the expression of resistin mRNA in the visceral adipose tissue of rats exposed to chronic immobilization stress. Materials and...

متن کامل

Imaging metabolite dynamics in living cells using a Spinach-based riboswitch.

Riboswitches are natural ligand-sensing RNAs typically that are found in the 5' UTRs of mRNA. Numerous classes of riboswitches have been discovered, enabling mRNA to be regulated by diverse and physiologically important cellular metabolites and small molecules. Here we describe Spinach riboswitches, a new class of genetically encoded metabolite sensor derived from naturally occurring riboswitch...

متن کامل

Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test

One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...

متن کامل

Single Cell Analysis of the Proinflammatory Responses of Mast Cell by a Real Time Secretion Assay

A real-time secretion monitoring assay from living single-cells was realized by total internal reflection fluorescence imaging with an optically optimized microwell array chip fabricated of an amorphous fluoropolymer, CYTOP on the basis of a fluorescence sandwich immunoassay. After individual mast cells were stimulated with lipopolysaccharide in the microwell array, their proinflammatory respon...

متن کامل

Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test

One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Scientific reports

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2015