Feasibility and reliability of an automated controller of inspired oxygen concentration during mechanical ventilation
نویسندگان
چکیده
INTRODUCTION Hypoxemia and high fractions of inspired oxygen (FiO2) are concerns in critically ill patients. An automated FiO2 controller based on continuous oxygen saturation (SpO2) measurement was tested. Two different SpO2-FiO2 feedback open loops, designed to react differently based on the level of hypoxemia, were compared. The results of the FiO2 controller were also compared with a historical control group. METHODS The system measures SpO2, compares with a target range (92% to 96%), and proposes in real time FiO2 settings to maintain SpO2 within target. In 20 patients under mechanical ventilation, two different FiO2-SpO2 open loops were applied by a dedicated research nurse during 3 hours, each in random order. The times spent in and outside the target SpO2 values were measured. The results of the automatic controller were then compared with a retrospective control group of 30 ICU patients. SpO2-FiO2 values of the control group were collected over three different periods of 6 hours. RESULTS Time in the target range was higher than 95% with the controller. When the 20 patients were separated according to the median PaO2/FiO2 (160(133-176) mm Hg versus 239(201-285)), the loop with the highest slope was slightly better (P = 0.047) for the more-hypoxemic patients. Hyperoxemia and hypoxemia durations were significantly shorter with the controller compared with usual care: SpO2 target range was reached 90% versus 24%, 27% and 32% (P < .001) with the controller, compared with three historical control-group periods. CONCLUSION A specific FiO2 controller is able to maintain SpO2 reliably within a predefined target range. Two different feedback loops can be used, depending on the initial PaO2/FiO2; with both, the automatic controller showed excellent performance when compared with usual care.
منابع مشابه
تاثیر تهویه مصنوعی نوسانی با فرکانس بالا در نارسایی شدید تنفسی نوزادان
Despite improvement of mechanical ventilation devices for infants, lung injury still causes morbidity and mortality in many cases. To determine the effect of high frequency oscillatory ventilation (HFOV) in infants with severe respiratory failure, 10 neonates were evaluated prospectively. Mean gestational age of these patients was 35 weeks and alveolar-arterial oxygen gradient (A-aDo2) and the ...
متن کاملAutonomous control of inspired oxygen concentration during mechanical ventilation of the critically injured trauma patient.
BACKGROUND Transport of mechanically ventilated patients in a combat zone presents challenges including conservation of resources. In the battlefield setting, the provision of adequate oxygen supplies remains a significant issue. Autonomous control of oxygen concentration may allow a reduction in mission load. METHODS Trauma patients requiring ventilation and inspired oxygen concentration (FI...
متن کاملتأثیر تهویه با حجمهای جاری متفاوت و تهویه دقیقهای ثابت بر روی دیاکسید کربن انتهای بازدمی
Background & Aims: Elimination of carbon dioxide is related to the alveolar ventilation, respiratory rate and tidal volume. The aim of this study to determine the effect of mechanical ventilation with different tidal volumes and constant minute ventilation on the end tidal Co2 and oxygen saturation during general anesthesia and to seek optimum parameters of mechanical ventilation during gener...
متن کاملتأثیر فشردن قفسه سینه در زمان بازدم قبل از ساکشن داخل تراشه بر تبادل گازهای خون شریانی بیماران تحت تهویه مکانیکی
Background & Aim : Endotracheal suctioning is one of the most frequently used methods for airway clearance in patients under mechanical ventilation. Chest physiotherapy techniques such as expiratory rib cage compression before endotracheal suctioning can be used as a means to facilitate mobilizing and removing airway secretions and improving alveolar ventilation. This study was carried out to...
متن کاملDiffusion of nitrous oxide into the pleural cavity.
We postulated that nitrous oxide transfer into the pleural cavity can occur by diffusion from the alveoli, independent of vascular transport. Under general anaesthesia, six sheep were studied in two phases, a control and an experimental phase. The sheep were anaesthetized, intubated, and received positive pressure mechanical ventilation. A catheter was placed in the right pleural cavity and 150...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 18 شماره
صفحات -
تاریخ انتشار 2014