Sentinel lymph node biopsy in breast cancer patients after overnight migration of radiolabelled sulphur colloid.

نویسندگان

  • N Lamichhane
  • K W Shen
  • C L Li
  • Q X Han
  • Y J Zhang
  • Z M Shao
  • Z Z Shen
چکیده

OBJECTIVE To evaluate the performance and feasibility of sentinel lymph node biopsy in breast cancer patients using technetium-99m (99mTc) sulphur colloid and gamma probe. METHODS From May 2000 to March 2001, 70 patients with a tumour less than 5 cm with clinically negative axillary lymph nodes underwent sentinel node biopsy followed by standard axillary dissection. 99mTc sulphur colloid was injected around the primary tumour the day before surgery and a gamma probe was used to detect the sentinel lymph node during the surgical procedure. Sentinel lymph node biopsy was compared with standard axillary dissection for its ability to accurately reflect the final pathological status of the axillary nodes. RESULTS The sentinel lymph node was successfully identified in 67 of 70 patients (95.71%). The number of sentinel lymph nodes ranged from 1-5 (mean 1.5) and non-sentinel nodes ranged from 5-22 (mean 13.3). Of the 67 patients with successfully identified sentinel lymph nodes, 43.28% (29/67) were histologically positive. Sensitivity of the sentinel lymph node to predict axilla was 82.75%; specificity was 100%. Positive and negative predictive values were 100% and 88.3% respectively. The sentinel lymph node was falsely negative in five patients, yielding an accuracy of 92.53%. Sentinel lymph node biopsy was more accurate for T1 tumours than for T2 tumours. CONCLUSIONS The gamma probe guided method after overnight migration of 99mTc sulphur colloid is technically feasible for detecting sentinel lymph nodes in most breast cancer patients, accurately predicting the axillary lymph node status, and appears more accurate for T1 lesions than for larger lesions. This minimally invasive axillary staging procedure represents a major advance in the surgical treatment of breast cancer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of peritumoral and subareolar injection of Tc99m sulphur colloid and blue-dye for detection of the sentinel lymph node in breast cancer.

BACKGROUND The new trend in diagnosis of the lymph node is sentinel node biopsy. This method has become increasingly accepted as a minimally invasive alternative to routine axillary dissection. Although the results of numerous studies have shown that sentinel node biopsy can accurately determine the axillary nodal status, the identification rates and false-negative rates have been variable. The...

متن کامل

The need for skin pen marking for sentinel lymph node biopsy: A comparative study

  Introduction: There is a consensus in the literature that sentinel lymph node biopsy is the standard procedure for axillary staging in early stage (I and II) breast cancer patients. Usually during lymphoscintigraphy, the location of the sentinel lymph node is marked on the skin by an indelible ink. In this study we evaluated this issue in our patients. Methods: 40 ...

متن کامل

Sentinel lymph node biopsy in melanoma patients: An experience with Tc-99m antimony sulfide colloid

  Introduction: Sentinel lymph node biopsy is the standard procedure for lymph node staging in intermediate thickness melanoma. In Iran, this procedure has not been addressed sufficiently. In this study, we report our experience in this area. Methods: Ten consecutive patients with intermediate thickness melanoma where included in our study. 1.5 mCi of Tc-99m antimony...

متن کامل

Lymphatic mapping and sentinel node biopsy in breast cancer.

BACKGROUND Sentinel lymph node biopsy is a recently developed, minimally invasive technique for staging the axilla in patients with breast cancer. It has been suggested that this technique will avoid the morbidity associated with more extensive axillary dissection. A wide range of different methods and materials has been employed for lymphatic mapping, but there has been little consensus on the...

متن کامل

Sentinel lymph node biopsy: technique validation at the Setúbal Medical Centre, Portugal

AIMS To evaluate the accuracy of sentinel lymph node biopsy in breast cancer patients at this institution, using combined technetium-99m ((99m)Tc) sulphur colloid and patent blue vital dye. METHODS From March 2007 to July 2008, 50 patients with a tumour of less than 3 cm and with clinically negative axillary lymph nodes underwent sentinel lymph node biopsy (SLNB), followed by axillary lymph n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Postgraduate medical journal

دوره 80 947  شماره 

صفحات  -

تاریخ انتشار 2004