Chromosome centromeres: structural and analytical investigations with high resolution scanning electron microscopy in combination with focused ion beam milling.
نویسندگان
چکیده
Whole mount mitotic metaphase chromosomes of different plants and animals were investigated with high resolution field emission scanning electron microscopy (FESEM) to study the ultrastructural organization of centromeres, including metacentric, acrocentric, telocentric, and holocentric chromosome variants. It could be shown that, in general, primary constrictions have distinctive ultrastructural features characterized by parallel matrix fibrils and fewer smaller chromomeres. Exposure of these structures depends on cell cycle synchronization prior to chromosome isolation, chromosome size, and chromosome isolation technique. Chromosomes without primary constrictions, small chromosomes, and holocentric chromosomes do not exhibit distinct ultrastructural elements that could be directly correlated to centromere function. Putative spindle structures, although rarely observed, spread over the primary constriction to the bordering pericentric regions. Analytical FESEM techniques, including specific DNA staining with Pt blue, staining of protein as a substance class with silver-colloid, and artificial loosening of fixed chromosomes with proteinase K, were applied, showing that centromere variants and ultrastructural elements in the centromere differ in DNA and protein distribution. Immunogold localization allowed high-resolution comparison between chromosomes with different centromere orientations of the distribution of centromere-related histone variants, phosphorylated histone H3 (ser10), and CENH3. A novel application of FESEM combined with focused ion beam milling (FIB) provided new insights into the spatial distribution of these histone variants in barley chromosomes.
منابع مشابه
High Speed TEM Sample Preparation by Xe FIB
Preparation of Transmission Electron Microscope (TEM) samples by Focused Ion Beam (FIB) milling is one of the most precise techniques now routinely used for example in failure analysis or material science. These TEM samples are commonly prepared using Ga FIB technology, starting more than 20 years ago [13]. Presently FIB columns are commonly combined with the Scanning Electron Microscopy (SEM) ...
متن کاملNeuroanatomy from Mesoscopic to Nanoscopic Scales: An Improved Method for the Observation of Semithin Sections by High-Resolution Scanning Electron Microscopy
Semithin sections are commonly used to examine large areas of tissue with an optical microscope, in order to locate and trim the regions that will later be studied with the electron microscope. Ideally, the observation of semithin sections would be from mesoscopic to nanoscopic scales directly, instead of using light microscopy and then electron microscopy (EM). Here we propose a method that ma...
متن کاملPreparation of high-quality planar FeRh thin films for in situ TEM investigations
The preparation of a planar FeRh thin film using a focused ion beam (FIB) secondary electron microscope (SEM) for the purpose of in situ transmission electron microscopy (TEM) is presented. A custom SEM stub with 45° faces allows for the transfer and milling of the sample on a TEM heating chip, whilst Fresnel imaging within the TEM revealed the presence of the magnetic domain walls, confirming ...
متن کاملImproved focused ion beam target preparation of (S)TEM specimen--a method for obtaining ultrathin lamellae.
Specimen quality is vital to (scanning) transmission electron microscopy (TEM) investigations. In particular, thin specimens are required to obtain excellent high-resolution TEM images. Conventional focused ion beam (FIB) preparation methods cannot be employed to reliably create high quality specimens much thinner than 20 nm. We have developed a method for in situ target preparation of ultrathi...
متن کاملUltrathin specimen preparation by a low-energy Ar-ion milling method.
The low-energy Ar-ion milling method was used to prepare ultrathin specimens for transmission electron microscope observation. The samples were thinned initially by a usual focused ion beam technique or typical Ar-ion milling with a high energy of 2-10 keV and were thinned additionally by an Ar-ion beam with an energy less than 1 keV, typically 500-900 eV. This low-energy ion beam was scanned o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cytogenetic and genome research
دوره 124 3-4 شماره
صفحات -
تاریخ انتشار 2009