Determination of the temperature rise within UHMWPE tibial components during tribological loading.

نویسندگان

  • Mathias C Galetz
  • Tobias Uth
  • Markus A Wimmer
  • Peter Adam
  • Uwe Glatzel
چکیده

The wear of ultrahigh molecular weight polyethylene (UHMWPE) is considered as one of the major reasons for revision of artificial joints. While in vivo measurements have shown a significant temperature increase in knee implants, the amount of heat dissipated within the UHMWPE tibial component and its influence on the friction behavior when paired with a cobalt-chromium (CoCrMo) femoral component is unknown. Our goal was to address these questions by measuring the temperature rise over a wide range of tribological loading conditions that mimic certain spots on artificial knee joints. The temperature rise as a function of lubricant, sliding velocity, coefficient of friction and maximum load was determined and analyzed. Additionally, the heat gradient during constant loading was investigated that allows the calculation of heat flow. The test setup consists of a wheel-on-flat laboratory testing device. Tests were performed in ambient air and different lubricants. During the tests, the temperature rise in the polyethylene was recorded with embedded thermocouples. The temperature rise was high and shown to be directly linked to load, coefficient of friction and relative velocity. Because it is generally assumed that the applied energy is an indicator for the development of wear in particles, some considerations for the design of knee joints are proposed based on our observations. The amount of heat dissipated in the polyethylene under cyclic loading was measured and is discussed in comparison with the theoretical model of temperature in friction pairs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An augmented hybrid constitutive model for simulation of unloading and cyclic loading behavior of conventional and highly crosslinked UHMWPE.

Ultra-high molecular weight polyethylene (UHMWPE) is extensively used in total joint replacements. Wear, fatigue, and fracture have limited the longevity of UHMWPE components. For this reason, significant effort has been directed towards understanding the failure and wear mechanisms of UHMWPE, both at a micro-scale and a macro-scale, within the context of joint replacements. We have previously ...

متن کامل

Potential of improving tribological performance of UHMWPE by engineering the Ti6Al4V counterfaces

Recently, some novel surface engineering techniques have been developed, which may be used for extending lifetime of artificial joints; however, the full potential will not be realised until the tribological behaviour of surface engineered bio-medical materials has been fully characterised. In the present investigation, a pin-on-disc tribometer has been used to evaluate the tribological respons...

متن کامل

Effect of cyclic strain on the mechanical behavior of virgin ultra-high molecular weight polyethylene.

Ultra High Molecular Weight Polyethylene (UHMWPE) is a polymeric material employed in critical biomedical applications. Knowledge of its mechanical behavior is essential in order to obtain accurate prediction of stresses and deformations in real components, in particular when cyclic loading is considered. In the present research the effects of alternating and pulsating cyclic strain on the mech...

متن کامل

Biomechanical evaluation of physeal-sparing fixation methods in tibial eminence fractures.

BACKGROUND Tibial eminence fractures occur most commonly in skeletally immature children. Several techniques using physeal-sparing fracture fixation have been described, but their structural properties have not been evaluated. PURPOSE To determine the strength and resistance to displacement of physeal-sparing techniques used to fix tibial eminence fractures. STUDY DESIGN Controlled laborato...

متن کامل

Nanoindentation of Polyethylene Tibial Components

Delamination is a common failure mechanism in ultra-high molecular weight polyethylene (UHMWPE) tibial inserts [Wright and Rimmnac, 1988]. Changes in polyethylene mechanical properties, such as subsurface embrittlement due to oxidation, may promote crack propagation. The assessment of through-thickness properties may, therefore, provide insight into delamination mechanisms. Using the small punc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta biomaterialia

دوره 6 2  شماره 

صفحات  -