Evaluation of efficacy of a pulse oximeter to assess pulp vitality.

نویسندگان

  • Mohammed Sadique
  • S V Ravi
  • Kunjamma Thomas
  • Prasanth Dhanapal
  • Elsy P Simon
  • Mohammed Shaheen
چکیده

BACKGROUND To evaluate the efficacy of pulse oximeter as a pulp vitality tester. MATERIALS AND METHODS The sample group consisted of 60 patients of age 15 to 30 years with normal maxillary anterior teeth. Thirty nonvital teeth with complete endodontic fillings were tested as control group. Systemic oxygen saturation values from the patient's fingers served as the control sample for comparison of pulp oxygen saturation values. Readings were recorded on index fingers first; teeth were then evaluated by placing sensor onto the tooth. RESULTS Nonvital teeth recorded oxygen saturation values of 0%. The mean value for central incisor was 85.11 (SD ± 2.07), for lateral incisors 80.21 (SD ± 2.03) and for canines 89.55 (SD ± 1.09). Their control values (patient's index fingers) averaged 95.88% (SD ± 0.66). Pearson's correlation analysis showed a correlation of 0.11 for central incisors, 0.19 for lateral incisors and 0.12 for canines. CONCLUSION This study confirms that pulse oximeter is effective equipment for pulp vitality testing. Pulse oximeter evidences the actual method of evaluating the pulp vitality compared to contemporary methods. How to cite the article: Sadique M, Ravi SV, Thomas K, Dhanapal P, Simon EP, Shaheen M. Evaluation of efficacy of a pulse oximeter to assess pulp vitality. J Int Oral Health 2014;6(3):70-2.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dental pulp neurophysiology: part 2. Current diagnostic tests to assess pulp vitality.

In this second part of our 2-part review, we discuss recent research about pulp tests that determine the vitality of the tooth and clinically accepted pulp testers. A pain response to hot, cold or an electric pulp tester indicates the vitality of only a tooth's pulpal sensory supply; the response does not give any idea about the state of the pulp. Although the sensitivity of these tests is high...

متن کامل

Comparative Study of Pulp Vitality in Primary and Young Permanent Molars in Human Children with Pulse Oximeter and Electric Pulp Tester

AIM AND OBJECTIVE The purpose of this study was to compare the pulp testing methods (pulse oximetry and electric pulp test) in primary and young permanent teeth of children. MATERIALS AND METHODS The study included a total of 155 children aged 4 to 15 years. Twenty children formed control group I. Study group included all healthy, 85 primary 2nd molars in group II and 85 permanent 1st molars ...

متن کامل

Pulse oximetry evaluation of vitality in primary and immature permanent teeth.

Present methods of assessing pulp vitality (electric and thermal testing) are of limited use with children, often resulting in false positive or false negative results. Pulse oximetry is a proven, atraumatic method of measuring vascular health by evaluating oxygen saturation (SaO2). This pilot study explores the use of a modified pulse oximetry ear probe to assess pulpal vascular oxygen saturat...

متن کامل

Evaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals

Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...

متن کامل

Evaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals

Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of international oral health : JIOH

دوره 6 3  شماره 

صفحات  -

تاریخ انتشار 2014