Decision-Tree Sensitivity Analysis for Cost-Effectiveness of Chest 2-Fluoro-2- D-[F]Fluorodeoxyglucose Positron Emission Tomography in Patients With Pulmonary Nodules (Non-small Cell Lung Carcinoma) in Japan*
نویسندگان
چکیده
Context: Recent studies have demonstrated the potential cost-effectiveness of using 2-fluoro-2D-[F]fluorodeoxyglucose (FDG) positron emission tomography (PET) in the management of non-small cell lung carcinoma (NSCLC), but because of differences in health-care systems, those findings may not hold true in a Japanese hospital. Objective: To assess the cost-effectiveness of the chest CT plus chest FDG-PET strategy in Japan. Design: Decision-tree sensitivity analysis based on the two competing strategies of chest CT–alone vs chest CT plus chest FDG-PET. Study selection: A simulation of 1,000 patients in whom NSCLC, stage IIIB or less, was suspected was created using baselines of other relevant variables in regard to sensitivity, specificity, mortality, life expectancy, and cost from published data. Methods: We surveyed the relevant literature for the choice of variables. Main outcome measures: Expected marginal cost and expected life expectancy gain for NSCLC patients. Results: The chest CT plus chest FDG-PET strategy yielded an expected life expectancy gain of 0.607 years (7.3 months) per patient, compared with the alternative strategy of chest CT–alone. Using an FDG-PET examination cost of 1.0 3 10 yen (around $700 US) per study, the cost increment was 2.18 3 10 yen/yr/patient. Conclusions: The chest CT plus chest FDG-PET strategy in patients with NSCLC is unlikely to be cost-effective in Japan. However, patient life expectancy gain would increase as a result of improved staging of NSCLC. These preliminary results should be confirmed by further studies for specific environments. (CHEST 2000; 117:346–353)
منابع مشابه
Decision-tree sensitivity analysis for cost-effectiveness of whole-body FDG PET in the management of patients with non-small-cell lung carcinoma in Japan.
BACKGROUND Whole-body 2-fluoro-2-D-[18F]deoxyglucose [FDG] positron emission tomography (WB-PET) may be more cost-effective than chest PET because WB-PET does not require conventional imaging (CI) for extrathoracic staging. METHODS The cost-effectiveness of WB-PET for the management of Japanese patients with non-small-cell lung carcinoma (NSCLC) was assessed. Decision-tree sensitivity analysi...
متن کاملAccuracy and cost-effectiveness of [18F]-2-fluoro-deoxy-D-glucose-positron emission tomography scan in potentially resectable non-small cell lung cancer.
STUDY OBJECTIVES This retrospective study of patients who were referred for surgical resection of non-small cell lung cancer (NSCLC) assessed the accuracy and cost-effectiveness of positron emission tomography (PET) with radiolabeled [18F]-2-fluoro-deoxy-D-glucose (FDG) in staging mediastinal lymph nodes (MLNs). DESIGN From January 2001 to September 2002, 90 patients with suspected or proven ...
متن کاملPrognostic value of various metabolic parameters on pre-treatment 18-F-FDG PET/CT in patients with stage I-III non-small cell lung cancer
Background: the aim of this study was to investigate the prognostic value of 18Fluorine-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) parameters in both overall survival and progression-free survival in Stage I-III non-small cell lung cancer (NSCLC). Materials and Methods: In this retrospective study, 267 patients who were diagnosed as Stage I-III non-smal...
متن کاملThe role of FDG-PET in the management of non-small cell lung carcinoma.
INTRODUCTION Positron emission tomography (PET) using 18F-2-fluoro-2 deoxy-D-glucose (FDG) has been widely investigated and used in the non-invasive imaging of malignancy. Non-small cell lung carcinoma (NSCLC) is one of the most common and best validated indications for an FDG-PET scan. This review examines the roles of FDG-PET in the management of NSCLC and attempts to identify emerging uses a...
متن کاملDoes whole-body 2-[18F]-fluoro-2-deoxy-D-glucose positron emission tomography have an advantage over thoracic positron emission tomography for staging patients with lung cancer?
BACKGROUND Whole-body (WB) positron emission tomography (PET) with 2-[(18)F]-fluoro-2-deoxy-D-glucose (FDG) is more accurate than other imaging studies for detecting lung cancer and extrathoracic metastatic disease. Thoracic PET (from the skull base through the kidneys) may be equally as useful as WB PET (skull base to mid-thigh). With the recent introduction of hybrid CT-PET systems, use of th...
متن کامل