Quantifying the influence of Bessel beams on image quality in optical coherence tomography
نویسندگان
چکیده
Light scattered by turbid tissue is known to degrade optical coherence tomography (OCT) image contrast progressively with depth. Bessel beams have been proposed as an alternative to Gaussian beams to image deeper into turbid tissue. However, studies of turbid tissue comparing the image quality for different beam types are lacking. We present such a study, using numerically simulated beams and experimental OCT images formed by Bessel or Gaussian beams illuminating phantoms with optical properties spanning a range typical of soft tissue. We demonstrate that, for a given scattering parameter, the higher the scattering anisotropy the lower the OCT contrast, regardless of the beam type. When focusing both beams at the same depth in the sample, we show that, at focus and for equal input power and resolution, imaging with the Gaussian beam suffers less reduction of contrast. This suggests that, whilst Bessel beams offer extended depth of field in a single depth scan, for low numerical aperture (NA < 0.1) and typical soft tissue properties (scattering coefficient, μs = 3.7 mm(-1) and high scattering anisotropy, g > 0.95), superior contrast (by up to ~40%) may be obtained over an extended depth range by a Gaussian beam combined with dynamic focusing.
منابع مشابه
Speckle Noise Reduction for the Enhancement of Retinal Layers in Optical Coherence Tomography Images
Introduction One of the most important pre-processing steps in optical coherence tomography (OCT) is reducing speckle noise, resulting from multiple scattering of tissues, which degrades the quality of OCT images. Materials and Methods The present study focused on speckle noise reduction and edge detection techniques. Statistical filters with different masks and noise variances were applied on ...
متن کامل2mm Catheter Design for Endoscopic Optical Coherence Tomography
A biophotonics catheter was conceived with collimation optics, an axicon lens, and custom design imaging optics yielding a 360 degree scan aimed at imaging within concave structures such as arteries and lung lobes. The large depth of focus is necessary to image a long-depth-range sample with constant transverse resolution in optical coherence tomography (OCT). There are two approaches to achiev...
متن کاملExploring Frequency Domain OCT Systems
Frequency domain optical coherence tomography allows for in-vivo nondestructive imaging at speeds two orders of magnitude faster than time domain methods while increasing the signal to noise ratio. These benefits are the result of acquiring information on all scatterers in a depth scan all the time. We explore methods of maintaining depth resolution through dispersion compensation and lateral r...
متن کاملScintillation of pseudo-Bessel correlated beams in atmospheric turbulence.
The concept of pseudo-Bessel correlated beams is introduced, and their scintillation properties on propagation through turbulence are investigated. By using the Rytov approximation, the scintillation index of pseudo-Bessel correlated beams is formulated in weak turbulence. The study of scintillation is extended into strong turbulence by numeric simulations. It is shown that by choosing an appro...
متن کاملA 5mm catheter for constant resolution probing in Fourier domain optical coherence endoscopy
A 5mm biophotonic catheter was conceived for optical coherence tomography (OCT) with collimation optics, an axicon lens, and custom design imaging optics, yielding a 360 degree scan aimed at imaging within concave structures such as lung lobes. In OCT a large depth of focus is necessary to image a thick sample with a constant high transverse resolution. There are two approaches to achieving con...
متن کامل