Effects of transverse fiber stiffness and central tendon on displacement and shape of a simple diaphragm model.

نویسندگان

  • A M Boriek
  • J R Rodarte
چکیده

Our previous experimental results (A. M. Boriek, S. Lui, and J. R. Rodarte. J. Appl. Physiol. 75: 527-533, 1993 and A. M. Boriek, T. A. Wilson, and J. R. Rodarte. J. Appl. Physiol. 76: 223-229, 1994) showed that 1) costal diaphragm shape is similar at functional residual capacity and end inspiration regardless of whether the diaphragm muscle shortens actively (increased tension) or passively (decreased tension); 2) diaphragmatic muscle length changes minimally in the direction transverse to the muscle fibers, suggesting the diaphragm may be inextensible in that direction; and 3) the central tendon is not stretched by physiological stresses. A two-dimensional orthotropic material has two different stiffnesses in orthogonal directions. In the plane tangent to the muscle surface, these directions are along the fibers and transverse to the fibers. We wondered whether orthotropic material properties in the muscular region of the diaphragm and inextensibility of the central tendon might contribute to the constancy of diaphragm shape. Therefore, in the present study, we examined the effects of stiffness transverse to muscle fibers and inextensibility of the central tendon on diaphragmatic displacement and shape. Finite element hemispherical models of the diaphragm were developed by using pressurized isotropic and orthotropic membranes with a wide range of stiffness ratios. We also tested heterogeneous models, in which the muscle sheet was an orthotropic material, having transverse fiber stiffness greater than that along the fibers, with the central tendon being an inextensible isotropic cap. These models revealed that increased transverse stiffness limits the shape change of the diaphragm. Furthermore, an inextensible cap simulating the central tendon dramatically limits the change in shape as well as the membrane displacement in response to pressure. These findings provide a plausible mechanism by which the diaphragm maintains similar shapes despite different physiological loads. This study suggests that changes of diaphragm shape are restricted because the central tendon is essentially inextensible and stiffness in the direction transverse to the muscle fibers is greater than stiffness along the fibers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Passive mechanics of muscle tendinous junction of canine diaphragm.

The diaphragmatic muscle tendon is a biaxially loaded junction in vivo. Stress-strain relations along and transverse to the fiber directions are important in understanding its mechanical properties. We hypothesized that 1) the central tendon possesses greater passive stiffness than adjacent muscle, 2) the diaphragm muscle is anisotropic, whereas the central tendon near the junction is essential...

متن کامل

Modeling the kinematics of the canine midcostal diaphragm.

The hypotheses that the chest wall insertion (CW) is displaced laterally during inspiration and that this displacement is essential in maintaining muscle curvature of the costal diaphragmatic muscle fibers were tested. With the use of data from three dogs, caudal, lateral, and ventral displacements of CW during both quiet, spontaneous inspiration and during inspiratory efforts against an occlud...

متن کامل

Shape and tension distribution of the passive rat diaphragm.

We developed an in vitro preparation to investigate shape and stress distribution in the intact rat diaphragm. Our hypothesis was that the diaphragm is anisotropic with smaller compliance in transverse fiber direction than along fibers, and therefore shape change may be small. After the animals were killed (8 rats), the entire diaphragm was excised and fixed into a mold at the insertions. Oxyge...

متن کامل

Shape and tension distribution of the active canine diaphragm.

Both diaphragm shape and tension contribute to transdiaphragmatic pressure, but of the three variables, tension is most difficult to measure. We measured transdiaphragmatic pressure and the global shape of the in vivo canine diaphragm and used principles of mechanics to compute the tension distribution. Our hypotheses were that 1) tension in the active diaphragm is nonuniform with greater tensi...

متن کامل

Nonlinear Buckling and Post-buckling of Shape Memory Alloy Shallow Arches

In this work, the nonlinear buckling and post-buckling behavior of shallow arches made of Shape Memory Alloy (SMA) is investigated. Arches are susceptible to large deflections, due to their slenderness, especially when the external load exceeds the serviceability limit point. Beyond this, loss of stability may occur, the famous snap-through buckling. For this reason, curved beams can be used in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 82 5  شماره 

صفحات  -

تاریخ انتشار 1997